Electrical installation – Lenze ELCAFHIxxx4D34NNPM Highline Benutzerhandbuch

Seite 73

Advertising
background image

Electrical installation

Safety engineering

4

l

73

EDKLCFH3024−XPM DE/EN 6.0

)

Note!

Please observe during transport, storage and operation:

ƒ

Cover unused connectors for control connections and interfaces with the
plastic covers provided to preserve the certified safety technology features.

X60 − Safe inputs, safe outputs

Pin

Signal

Description

Data

Connector: female, 26−pin, M27, N−coded

1

n. c.

Not assigned

2

n. c.

Not assigned

3

n. c.

Not assigned

4

n. c.

Not assigned

5

n. c.

Not assigned

6

n. c.

Not assigned

7

CLB

Clock output, channel B

Only for passive sensors

8

CLA

Clock output, channel A

9

GCL

Reference potential for CLA and CLB

10

I1A

Sensor input 1, channel A

Only for equivalent switching passive
sensors

11

I1B

Sensor input 1, channel B

12

GI1

Reference potential for I1A and I1B

13

I2A

Sensor input 2, channel A

Only for equivalent switching passive
sensors

14

I2B

Sensor input 2, channel B

15

GI2

Reference potential for I2A and I2B

16

n. c.

Not assigned

17

n. c.

Not assigned

18

n. c.

Not assigned

19

I4A

Sensor input 4, channel A

Only for active sensors

20

I4B

Sensor input 4, channel B

21

GI4

Reference potential for I4A and I4B

22

AIE

Error confirmation input
(Acknowledge Input Error)

23

n. c.

Not assigned

24

n. c.

Not assigned

25

n. c.

Not assigned

26

n. c.

Not assigned

Advertising