2 rated data, Rated data, Technical data – Lenze ELCAFHIxxx4D34NNPM Highline Benutzerhandbuch

Seite 59: 2 rated data input data, Output data

Advertising
background image

Technical data

Rated data

2

l

59

EDKLCFH3024−XPM DE/EN 6.0

2.2

Rated data

Input data

Basis of the data

Mains

Mains voltage U

LN

[V]

Voltage range U

LN

[V]

Frequency range

[Hz]

3/PE AC

400

320 − 0 % ... 440 + 0 %

45 ... 65

3/PE AC

500

400 − 0 % ... 550 + 0 %

45 ... 65

Cyclic mains switching

Type

ELCAFHI7514

Max. 5 switchings / 5 minutes

ELCAFHI1524

ELCAFHI3024

Voltage

Frequency

Current (T

a1

)

1)

Current (T

a2

)

2)

Number

of phases

Typ

[V]

[Hz]

[A]

[A]

ELCAFHI7514

400/500

50/60

3.3/2.6

2.1/1.6

3

ELCAFHI1524

400/500

50/60

5.5/4.4

3.4/2.8

3

ELCAFHI3024

400/500

50/60

9.0/7.9

5.6/4.9

3

1)

Ta1 = max. 40 °C ambient temperature during operation

2)

Ta2 = max. 55 °C ambient temperature during operation

Supply voltage for control electronics of the controller
(safely separated power supply unit SELV/PELV)

Typ

Voltage range U

DC

[V DC]

Current consumption at + 24 V DC [A]

Min.

1)

Max.

2)

ELCAFHI7514

+ 24

(+19.2 − 0 % ... +28.8 + 0 %)

1.9

4.4

ELCAFHI1524

ELCAFHI3024

1)

No digital inputs and outputs connected

2)

All digital inputs and outputs connected

Output data

Voltage

Frequency

Current (T

a1

)

1)

Current (T

a2

)

2)

Number

of phases

Typ

[V]

[Hz]

[A]

[A]

ELCAFHI7514

0 ... 400/500

0 ... 480

2.5/2.1

1.6/1.3

3

ELCAFHI1524

0 ... 400/500

0 ... 480

5.5/4.4

3.4/2.8

3

ELCAFHI3024

0 ... 400/500

0 ... 480

7.3/6.4

4.6/4.0

3

1)

Ta1 = max. 40 °C ambient temperature during operation

2)

Ta2 = max. 55 °C ambient temperature during operation

Power loss P

V

[W]

Type

when operating with rated output current I

aN

when controller is inhibited

ELCAFHI7514

112

40

ELCAFHI1524

138

ELCAFHI3024

211

Advertising