30 error code 0x002b, 31 error code 0x002c, 32 error code 0x002d – BECKHOFF EL9xxx Benutzerhandbuch

Seite 90

Advertising
background image

Anhang

7.4.30

Error Code 0x002B

Meaning

No Valid Inputs and Outputs

Description

n/a

Current State (or state change)

O, S→O

Resulting state

S + E

Solution

n/a

7.4.31

Error Code 0x002C

Meaning

Fatal Sync Error

Description

The hardware interrupt signal (so called Sync signal) generated by the ESC is not generated any more. The
master sets and activated the cycle time of the Sync signal during state transition from PREOP to SAFEOP.
If a slave was disconnected and reconnected (also due to lost frames or CRC errors) the generation of the
SyncSignal may be lost.

Current State (or state change)

O

Resulting state

S + E

Solution

Set master to INIT and back to OP so that the DCs are initialized again

7.4.32

Error Code 0x002D

Meaning

ana