Bronkhorst RS232 interface Benutzerhandbuch

Seite 43

Advertising
background image

Parameter

number

(DDE)

Parameter

name

Group

0

Group

1

Group

2

Process

number

FB
nr

(par)

Var

Type

Var

Length

Min

value

Max

value

Read

Write

Poll

Secured

Highly

Secured

Default Value

Description

2011-05-18 Page 5 of 5

FlowDDE database version

V3.64

DDE str

276

Sub fluid number

3

65

1

c

0

255

Yes

Yes

No

No

No

0

Sub fluid number

FluidSub

277

Temperature compensation factor

9

116

17

f

-3.40282E+38

3.40282E+38

Yes

Yes

No

Yes

No

0

Temperature compensation factor

FreqTCor

278

DSP register address

13

116

29

l

0

4294967295

Yes

Yes

No

No

No

0

DSP register address

DSPRegI

279

DSP register long

13

116

30

l

-4294967295

4294967295

Yes

Yes

No

Yes

No

0

DSP register long

DSPRegLng

280

DSP register floating point

13

116

30

f

-3.40282E+38

3.40282E+38

Yes

Yes

No

Yes

No

0

DSP register floating point

DSPRegFlt

281

DSP register integer

13

116

31

i

-65535

65535

Yes

Yes

No

Yes

No

0

DSP register integer

DSPRegInt

282

Standard deviation

19

121

0

f

-3.40282E+38

3.40282E+38

Yes

No

Yes

No

No

0

Standard deviation

StdDev

283

Measurement status

19

121

1

i

0

65535

Yes

No

No

No

No

0

Measurement status

MeasStatus

284

Measurement stop criteria

19

121

2

i

0

65535

Yes

No

No

No

No

0

Measurement stop criteria

MStopCrit

285

Measurement time out

20

121

3

i

0

65535

Yes

Yes

No

No

No

0

Measurement time out

MTimeOut

286

Maximum number of runs

20

121

4

i

0

65535

Yes

Yes

No

No

No

0

Measurement maximum number of runs

MMaxNrRuns

287

Minimum standard deviation

20

121

5

f

-3.40282E+38

3.40282E+38

Yes

Yes

No

No

No

0

Measurement minimum standard deviation

MMinStdDev

288

IO switch status

10

114

31

l

0

4294967295

Yes

Yes

No

No

No

0

IO status for switches

IOSwitchSt

295

Sensor bridge settings

9

65

21

i

0

65535

Yes

Yes

No

Yes

Yes

513

Sensor bridge settings

SensBridge

296

Sensor bridge current

9

65

22

f

0

3.40282E+38

Yes

Yes

No

Yes

Yes

0

Sensor bridge current (0..0.02A)

SensCurren

297

Sensor resistance

9

65

23

f

0

3.40282E+38

Yes

No

No

No

No

0

Sensor resistance (Ohm)

SensResist

298

Sensor bridge voltage

9

65

24

f

0

3.40282E+38

Yes

No

No

No

No

0

Sensor bridge voltage (0..11.5V)

SensVolt

299

Sensor group name

9

65

25

c

-2

Yes

No

No

No

No

Sensor name (based on sensor detection / sensor resistance)

SensName

300

Sensor calibration temperature

9

116

20

f

-3.40282E+38

3.40282E+38

Yes

Yes

No

Yes

No

0

Sensor temperature at calibration

SensCalTmp

301

Valve safe state

8

115

31

c

0

255

Yes

Yes

No

No

No

0

Valve safe state

ValveSafe

302

Counter unit type index

16

104

12

c

0

255

Yes

Yes

No

No

No

0

Counter unit type

CnUnitType

303

Counter unit type

16

104

13

c

20

Yes

Yes

No

No

No

Counter unit type name

CnUnTypNam

304

Counter unit index (ext)

16

104

14

c

0

255

Yes

Yes

No

No

No

0

Counter unit index (extended counter unit table)

CnUnit

305

Bus1 selection

23

125

8

c

0

255

Yes

Yes

No

Yes

No

255

Fieldbus select

Bus1Select

306

Bus1 medium

23

125

11

c

0

255

Yes

Yes

No

Yes

No

1

Fieldbus medium id

Bus1Medium

307

Bus2 mode

23

124

7

c

0

255

Yes

Yes

No

Yes

No

0

Fieldbus2 mode

Bus2Mode

308

Bus2 selection

23

124

8

c

0

255

Yes

Yes

No

Yes

No

2

Fieldbus2 select

Bus2Select

309

Bus2 address

23

124

10

c

0

255

Yes

Yes

No

Yes

No

2

Fieldbus2 address (side interface)

Bus2Addr

310

Bus2 baudrate

23

124

9

l

0

10000000000

Yes

Yes

No

Yes

No

12000000

Fieldbus2 baudrate (side interface)

Bus2Baud

311

Bus2 medium

23

124

11

c

0

255

Yes

Yes

No

Yes

No

0

Fieldbus2 medium id

Bus2Medium

312

Bus2 diagnostics

23

124

20

c

-2

Yes

No

No

No

No

Fieldbus2 diagnose string (side interface)

Bus2Diagn

313

Bus2 name

23

124

21

c

-2

Yes

No

No

No

No

Propar

Fieldbus2 name (side interface)

Bus2Name

314

PIO channel selection

10

120

0

c

0

255

Yes

Yes

No

No

No

0

PIO channel selection

PIOChSel

315

PIO parameter

10

120

2

i

0

65535

Yes

Yes

No

No

No

0

PIO parameter connected to i/o channel (=process number*256+parameter number)

PIOParm

316

PIO input/output filter

10

120

6

f

-3.40282E+38

3.40282E+38

Yes

Yes

No

No

No

0

PIO input/output filter constant (0..1, 0=max, 1=min)

PIOFilter

317

PIO parameter capacity 0%

10

120

7

f

-3.40282E+38

3.40282E+38

Yes

Yes

No

No

No

0

PIO parameter capacity, 0% value

PIOPrmCap0

318

PIO parameter capacity 100%

10

120

3

f

-3.40282E+38

3.40282E+38

Yes

Yes

No

No

No

0

PIO parameter capacity, 100% value

PIOPrmCap

319

PIO configuration selection

10

120

1

c

0

255

Yes

Yes

No

No

No

0

PIO i/o channel configuration selection

PIOCfgSel

320

PIO analog zero adjust

10

120

4

f

-3.40282E+38

3.40282E+38

Yes

Yes

No

Yes

No

0

PIO analog input/output, zero adjust value

PIOAnZA

321

PIO analog span adjust

10

120

5

f

-3.40282E+38

3.40282E+38

Yes

Yes

No

Yes

No

0

PIO analog input/output, span adjust factor

PIOAnSA

322

PIO hardware capacity max

10

120

8

f

-3.40282E+38

3.40282E+38

Yes

Yes

No

No

No

0

PIO max hardware capacity (max capacity value in i/o units, V, A, Hz, etc.)

PIOHwCapMx

323

PIO capacity set selection

10

120

9

c

0

255

Yes

Yes

No

No

No

0

PIO capacity set selection

PIOCapSel

324

PIO hardware capacity 0%

10

120

10

f

-3.40282E+38

3.40282E+38

Yes

Yes

No

No

No

0

PIO hardware capacity, 0% value (capacity value in i/o units, V, A, Hz, etc.)

PIOHwCap0

325

PIO hardware capacity 100%

10

120

11

f

-3.40282E+38

3.40282E+38

Yes

Yes

No

No

No

0

PIO hardware capacity, 100% value (capacity value in i/o units, V, A, Hz, etc.)

PIOHwCap

326

Hardware platform id

12

0

6

i

0

65535

Yes

No

No

No

No

0

Hardware platform identification number

HardwId

327

Hardware platform sub id

12

0

7

c

0

255

Yes

No

No

No

No

0

Hardware platform sub identification number

HardwSubId

328

Temporary baudrate

23

124

31

l

0

10000000000

Yes

Yes

No

No

No

0

Temporary volatile Fieldbus2 baudrate (side interface)

TempBaud

329

Setpoint monitor mode

2

115

23

c

0

255

Yes

Yes

No

Yes

No

0

Monitor mode for setpoint

SetMonitor

330

BHT12

14

118

12

l

0

10000000000

Yes

No

No

No

No

0

Special BHT parameter

BHT12

331

Nominal sensor voltage

9

65

26

f

0

3.40282E+38

Yes

Yes

No

Yes

No

0

Nominal sensor voltage (used for sensor temperature voltage compensation)

SenNomVolt

332

Sensor voltage compensation factor

9

116

16

f

-3.40282E+38

3.40282E+38

Yes

Yes

No

Yes

No

0

Sensor voltage compensation factor (used for sensor temperature voltage comp.)

VoltTCor

333

PCB serial number

4

119

31

c

-2

Yes

Yes

No

Yes

Yes

PCB serial number (unique number or string written by PCB manufacturer)

PCBSerial

334

Minimum measure time

20

115

24

c

0

255

Yes

Yes

No

No

No

0

Minimum measure time between sensors of a piston prover in 0.1 seconds

MinMTime

335

Bus1 parity

23

125

12

c

0

255

Yes

Yes

No

Yes

No

0

Fieldbus parity

Bus1Parity

336

Bus2 parity

23

124

12

c

0

255

Yes

Yes

No

Yes

No

0

Fieldbus2 parity (side interface)

Bus2Parity

337

Firmware id

12

0

8

c

0

255

Yes

No

No

No

No

0

Firmware identification number

FirmwId