Please note that an infrared remote control can only be used up to a certain distance from the unit.
Objects situated between the Visualizer and the infrared remote control, and weak batteries, interfere
with the reception. If the Visualizer can only be controlled from a close distance, or if it cannot be
controlled at all with the infrared remote control, you may have to change the batteries. Open the cover
on the back of the remote control by hand and replace the two 1.5 V AA batteries with new ones.
Check the polarity of the batteries!

on-

screen menu, by pressing the menu-key

(#23) for one second, go

to

(#14)

(#13) - each time this key combination is used, the code switches from A
to B, C, D ... A ...etc. For resetting the remote control to code A
simultaneously p

.

The LED shows the selected code (it flashes one-time for code A,
two-times for code B, three-times for code C and four-times for code D)

If a user wants to work with a number of WolfVision Visualizers
simultaneously, each unit can be set to a different infrared code,
so up to 4 units can be controlled individually with their remote controls.
To change the infrared codes on the Visualizer, enter the

"Misc. Settings" and set the "IR Code" to A, B, C or D (code A is

default). To change the infrared code on the remote control,
simultaneously press

PRESET 1, PRESET 2

and

ZOOM TELE

ress

PRESET 1, PRESET 2 and ZOOM WIDE

10

INFRARED REMOTE CONTROL

front

back (open)

-

+

-

+

X

X

MENU

POWER

ZOOM

MIRROR

L

A

S

E

R

EXT / INT

ALL

TEXT

FOCUS

IRIS

1

2

3

A

A

AF

MEMORY

1

2

3

4

5

6

7

8

9

HELP

PRESETS

IMAGE TURN

LIGHT

AUTOMATIC LAMP CHANGER

The Visualizer is fitted with an automatic lamp changer. If one lamp fails, there is no need
to replace it immediately, as the automatic lamp changer automatically switches to the second

(spare)

lamp. When the unit changes

lamps there is an on-screen message saying: "Changing lamp".

When switching on the unit the Visualizer checks if both lamps are working. If one lamp fails there will
be an

on screen message for a couple of seconds displaying "Lamp x blown". This prevents a user

from forgetting to change a defective lamp.

If a lamp is not fully defective but worn out and as a result the light output is quite weak, you can switch
manually to the second lamp by pressing the

LIGHT-key (#21) for 2 seconds.

THERMOSTAT

If the unit gets too hot (improper ventilation or air extraction) a built in thermostat will switch off the light
of the Visualizer. Verify that proper ventilation and air extraction is available and allow the unit to cool.

EXCHANGING LAMPS

1. Turn the unit off

(#28) and disconnect the

power cord!

2. Remove the bottom light (#9) by pulling the
two spring catches (situated left and right of
the control panel) to the front and lift up the
bottom light plate.

3. Remove the lamp exchange cover

(#11)

by turning anti-clockwise and lift it.

4. Change the lamp (or both lamps)

Before changing the lamp allow it to cool or use a cloth to avoid burning a finger! When pressing a new
lamp into the socket use a cloth to prevent fingerprints on the lamp!

Only use 12 V/100 W halogen lamps (socket: GY 6,35), type: Osram HLX 64623,
Ansi EVA, LIF M/28 NAED 54052. These are relatively inexpensive standard OHP lamps.

Lamp exchange