SERIAL PORT / SERIAL PROTOCOL

9-pin D-Sub connector
on unit, male, front side

5

9

2

7

3 4

8

1

6

Pins:

2: RX, 3: TX, 5: GND, 7: RTS, 8: CTS

Baud rate:

9200, 19200, 38400, 57600 or 115200 (selectable)
databits: 8, stopbit: 1, parity: no

Please note: DecimaI-Codes (=ASCII-Codes or Hex-Codes) must be sent as one
single byte (e.g. 199 and not: 1 + 1 + 9) !

The serial port can be used to control the Visualizer through an external device, like a remote control
system for a complete conference room.

A detailed description of the serial protocol (including status

report and position setting) can be

downloaded from our website:

http://www.wolfvision.com/support.

DVI PORT

13

Pin 24

Pin 8

Pin 1

Pin 9

Pin 17

C4

C1

C2

C3

C5

1

- T.M.D.S. Data2-

9

- T.M.D.S. Data1-

17

- T.M.D.S. Data0-

2

- T.M.D.S. Data2+

10

- T.M.D.S. Data1+

18

- T.M.D.S. Data0+

3

- T.M.D.S. Data2/4 Shield

11

- T.M.D.S. Data1/3 Shield

18

- T.M.D.S. Data0+

4

- T.M.D.S. Data4- (*)

12

- T.M.D.S. Data3- (*)

19

- T.M.D.S. Data0/5 Shield

5

- T.M.D.S. Data4+(*)

13

- T.M.D.S. Data3+ (*)

20

- T.M.D.S. Data5- (*)

6

- DDC Clock

14 - +5V Power

21

- T.M.D.S. Data5+ (*)

7

- DDC Data

15

- Ground (return for +5V,

22

- T.M.D.S. Clock+

8

- Analog Vertical Sync

HSync and Vsync)

23

- T.M.D.S. Clock-

C1

- Analog Red

16

- Hot Plug Detect

24

- Analog Vertical Sync

C4

- Analog Horizontal Sync

C2

- Analog Green

C3

- Analog Blue

C - Analog Ground

(analog R, G & B return)

*...not used

Before changing a fuse disconnect the power cable. The fuse

(#34)

is situated behind a small lid above the power socket and the main
power switch. It can easily be opened with a small screwdriver etc..

Please put the new fuse(s) carefully into the socket, and put the socket
the right way round into the socket holder.

The type of fuse is: T 3,15A. Do not use any other type !


Change the fuse for a new one and switch the unit on. If the fuse fails
again contact your WolfVision Visualizer dealer!

EXCHANGING A FUSE

IMPORTANT

MIRROR - CLEANING

Mirror:

Please note that dust on the base mirror

(#2) inside the unit

has little effect on the picture quality (as it is out of the
focal range). However the top mirror

(#3) always has to be kept clean!

Wipe the mirror gently with the supplied WolfVision cleaning tissue!

Normal dry cleaning or cleaning together with breathing a bit on the mirror should be sufficient

(If not, use a special optical cleaner only!)

Please note: Switch off the power before cleaning a mirror in order to make sure that the Laser Center
Marker is off.

CAUTION: Sensitive front coated mirror!
Move the tissue in vertical direction only ! (horizontal scratches
would cause ugly reflections) Avoid high pressure !

DO NOT USE ORDINARY GLASS CLEANER OR ALCOHOL
- THE RESULT WOULD BE A SLIGHTLY BLUE MIRROR SURFACE !

The glass covering the mirror inside the unit should also be kept clean.
Cabinet:

Clean the cabinet by gently wiping it with a soft cloth.
Never use strong cleaning agents such as benzene or alcohol!