6 alignment with the led targeting light, Alignment with the led targeting light, 6alignment with the led targeting light – LumaSense Technologies IS 210 Benutzerhandbuch

Seite 8

Advertising
background image

IMPAC pyrometers IS 210 · IGA 210

8

Type

a:M *

)

Optics =

a [mm]

M

90

[mm]

a

1

[mm]

M

1

[mm]

a

2

[mm]

M

2

[mm]

D

[mm]

(MB 18)

130:1

4.5

15

28

(MB 25)

240:1

600

2.5

1000

12

1500

23

13

(MB 18)

140:1

7

15

24

(MB 25)

240:1

1000

4.2

1500

12

2000

19

16

(MB 18)

135:1

11

17

32

IS 210

(MB 25)

235:1

1500

6.4

2000

14

3000

23

17

165:1

300

1.8

400

6

600

15

17

175:1

350

2

500

8

800

18

16

145:1

500

3.4

800

11

1000

16

14

150:1

600

4

1000

13

1500

24

13

140:1

1000

7

1500

14

2000

22

16

IGA 21

0

MB 13L

+

MB 18L

150:1

1500

10

2000

17

3000

30

17

*

)

a:M; distance ratio (90% intensity)



Spot sizes for distances which are different from the nominal distance of the selected optics
may be calculated using the following formula:

D

)

D

M

(

a

a

M

2

2

D

)

D

M

(

a

a

M

1

1


6

Alignment with the LED targeting light


For exact measurement of the object temperature the pyrometer must be aligned correctly
onto the object. For this alignment the pyrometers are equipped with a LED targeting light.
This light enables the simple and accurate alignment even onto small objects.
The light point marks the center of the spot, not the exact size. The correct focusing distance
with the smallest spot size is achieved when the LED point has its smallest size. The targeting
light does not effect the temperature measurement.

M

Spot size [mm]

Measuring distance [mm]

a

M

1

a

1

M

2

a

2

Ø M

1

Ø M

Ø M

2

a

1

a

2

a

Ø D

Advertising