IMPAC pyrometer IGA 15 plus

9

5

Display functions / Setting keys


Additionally to the temperature measurement the IGA 15 plus provides some more functions which
are necessary for a correct measurement and usefully enlarging the functionality of the pyrometer.


Temperature display

Parameter / function


Laser targeting light function on / off


Indication °C or °F


Parameter value / function value

Setting keys:
1) Parameter selection PAR
2) change of parameter values:


Indication °C or °F:

indicates the temperature in °C or °F.

Temperature display:

shows the actual or stored temperature value.

Parameter / function:

selecting a parameter or a measuring function for indication or changing a

corresponding short form will be displayed.

Parameter value / function value:

indicates the value of the adjusted parameters or the tempera-

ture of the selected measuring function.

PAR key:

Repeated pushing of the PAR key displays all available parameters (as EMI, HI, INT,

C/F) or additional measuring functions in the following sequence mentioned below. Parameters
are part of the basic settings of the pyrometer. They are only displayed during adjustment. Meas-
uring functions are displayed additionally to the measuring temperature (MAX, MIN, AVG, DIF),
can give an acoustic signal (HI) or can be used for data analysis (RCL). Selected measuring
functions are stored when the pyrometer is switched off and will be activated by restarting the
instrument.

PAR

Display

Parameter /
function

Short explanation

Factory

settings

1 x

EMI

Emissivity indication

and

setting of emissivity

100

2 x

MAX

Max. value

indication of maximum value

-

3 x

MIN

Min. value

indication of minimum value

-

4 x

AVG

Average

indication of average value

-

5 x

DIF

Difference

indication of the difference between the actual meas-
uring temperature and the start measuring temperature

-

6 x

HI

Hi alarm

indication and setting of acoustic alarm

1800°C

7 x

CLR

Clear

deletes the stored measured values

8 x

STO

#

Store

fixing of storage position

9 x

RCL

#

Recall

indication of stored measured values

10 x

INT

Interval

indication and setting of time interval for storage of
measured values in continuous mode

OFF

11 x

C / F

Celsius

/

Fahrenheit

indication and setting of temperature reading
in °C or °F

C


Arrow keys:
With the arrow keys ▲ and ▼ the corresponding settings for all parameters can be changed. A
change in setting of a parameter is stored automatically.