Design and function, Transport, packaging and storage – WIKA GTU-10 Benutzerhandbuch

Seite 9

Advertising
background image

9

WIKA operating instructions portable SF

6

gas transfer unit, model GTU-10

14051107.01 06/2013 GB/D

GB

3. Specifications / 4. Design and function / 5. Transport, ...

3. Specifications

Gas flow rate:

1.1 m

3

/h (Option: 1.8 m

3

/h)

Maximum pressure:

40 bar abs.

Pressure reducer, outlet pressure: 0 ... 16 bar

Voltage supply:

AC 230 V, 50 Hz (Option: AC 115 V, 60 Hz)

Fuse with 10 A, slow

Operating temperature:

5 ... 40 °C

Weight:

35 kg (with 1.8 m

3

/h)

30 kg (with 1.1 m

3

/h)

Ingress protection:

IP 20

For further specifications see WIKA data sheet SP 63.07 and the order documentation.

4. Design and function

4.1 Short description

With the GTU-10, the user has the option of a pressure-reduced output to fill a gas

chamber with a preset pressure. From this output, the outlet pressure can be set between

0 ... 16 bar.

If, however, the unreduced output is connected, the GTU-10 has the capability to

compress the gas in the vessel to a maximum of 40 bar, and then automatically switch

off. Thus, the GTU-10 gas transfer unit can liquefy SF

6

gas to reduce volume.

4.2 Scope of delivery

Cross-check scope of delivery with delivery note.

5. Transport, packaging and storage

5.1 Transport

Check the portable SF

6

gas transfer unit for any damage that may have been caused by

transport. Obvious damage must be reported immediately.

Only move the unit using the appropriate materials handling equipment e.g. trolley.

Operation of the unit during transport is not permitted.

During any transport, the unit should be secured in accordance with local load regula-

tions. The applicable local safety regulations should be complied with.

OI_14051107_GTU-10_GB_D.indd 9

13.06.2013 11:28:13