Operating instructions safety switches nz.h/p...as – EUCHNER NZ.H/PxxxAS1 Benutzerhandbuch
Seite 5

Operating Instructions Safety Switches NZ.H/P...AS
1
EUCHNER GmbH + Co. KG Kohlhammerstraße 16 D-70771 Leinfelden-Echterdingen Tel. +49/711/75 97-0 Fax +49/711/75 33 16 www.euchner.de [email protected]
Subject to technical modifications; no r
esponsibility is accepted for the accuracy of this information. © EUCHNER GmbH + Co. KG
095119-03-12/11 (translation of the original operating instructions)
It may be necessary to set the synchronization
time to higher values. This depends on the
application and the approach speed of the dog.
f
With start-up test (corresponding to risk analysis)
In this operating mode, the safety guard must be
opened each time prior to restarting in order to
perform the start-up test.
f
LED indicators
The AS-Interface bus status is indicated by two
LEDs (Power, Fault).
Functional check
Warning! Danger of fatal injury as a result of
faults in installation and functional check.
Before carrying out the functional check, make
sure that there are no persons in the danger
area. Observe the valid accident prevention
regulations.
After installation and any fault, the safety function
must be fully checked. Proceed as follows:
f
Mechanical function test
Check the actuating element for freedom of
movement.
f
Electrical function test
1. Switch on operating voltage.
2. Close all safety guards.
f
The machine must not start automatically.
3. Enable operation in the control system.
4. Open the safety guard.
f
The machine must switch off and it must not be
possible to start it as long as the safety guard is
open.
Repeat steps 2 - 4 for each safety guard.
Inspection and service
If damage or wear is found, the complete
switch and actuator assembly must be
replaced.
Replacement of individual parts or assemblies
is not permitted!
Note: The year of manufacture can be seen in the
bottom, right corner of the rating plate.
No servicing is required, but regular inspection
of the following is necessary to ensure trouble-free
long-term operation:
f
correct switching function
f
secure mounting of components
f
dirt and wear
f
sealing of cable entry
f
loose plug connectors.
Exclusion of liability under the following
circumstances
f
incorrect use
f
non-compliance with safety regulations
f
installation and electrical connection not
performed by authorized personnel
f
failure to perform functional checks.
EC declaration of conformity
The manufacturer named below herewith declares
that the product fulfills the provisions of the
directive(s) listed below and that the related
standards have been applied.
EUCHNER GmbH + Co. KG
Kohlhammerstraße 16
70771 Leinfelden-Echterdingen, Germany
Directives applied:
f
Machinery directive 2006/42/EC
Standards applied:
f
EN 60947-5-1:2004 + Cor.:2005 + A1:2009
f
EN 1088:1995+A2:2008
Leinfelden, July 2010
Dipl.-Ing. Michael Euchner
Director
Duc Binh Nguyen
Authorized representative empowered to draw up
documentation
The signed EC declaration of conformity is included
with the product.
Technical data
Parameters
Value
Housing material
Anodized
die-cast alloy
Deg. of prot. acc. to IEC 60529 IP 67, mating connector plugged
Mechanical life
30x10
6
operating cycles
Ambient temperature
-25 ... +70°C
Degree of contamination
(external, acc. to EN 60947-1)
3 (industrial)
Installation position
Any
Actuator
HB
HS
PB
PS
Approach speed, max.
300
60
120
30
m/min
Approach speed, min.
0.1
0.1
0.5
0.5
m/min
Actuating force, min.
15 N
Weight
0.35 kg
Switching principle
2 positively driven NC contacts,
slow-action switching contact
EMC protection requirements
Acc. to EN 50295 (AS-Interface
standard) and IEC 62026
Connection
M12 plug connector
AS-Interface data acc. to
EA code: 7
AS-Interface specification 2.1
ID code: B
Operating voltage AS-Interface
DC 22.5 ... 31.6 V
Total current consumption, max. 45 mA
Valid AS-Interface addresses
1 - 31
AS-Interface inputs
In accordance with AS-Interface
Safety at Work
Positively driven NC contact 1
D0, D1
Positively driven NC contact 2
D2, D3
AS-Interface outputs
D1
Red LED, 1 = LED on
D2
Green LED, 1 = LED on
AS-Interface LED Power
Green, AS-Interface voltage present
AS-Interface LED Fault
Red, offline phase or address 0
Reliability values acc. to EN ISO 13849-1
B10d
2 x 10
7
Status table
Programming
State
D0, D1
D2, D3
Monitor diagnosis
Green
Safety guard closed
Code sequence
If start-up test selected:
yellow flashing on start-up
2-channel
Intermediate state during opening or closing
dependent
of the safety guard.
Half-seq.
00
During opening: yellow flashing
Synchronization time
Switch S1 (internal) open
During closing: red
3 s
Intermediate state during opening or closing
After expiration of the synchronization time:
of the safety guard.
00
Half-seq.
yellow flashing
Switch S2 (internal) open
Safety guard open
00
00
Red
Address 0 or communication disrupted
–
Gray