Operating instructions safety switches nz.h/p...as – EUCHNER NZ.H/PxxxAS1 Benutzerhandbuch
Seite 6
Advertising

Operating Instructions Safety Switches NZ.H/P...AS
1
Figure 5: Travel diagrams
Figure 6: Dimension drawing safety switch NZ1H...AS1
Figure 7: Dimension drawing safety switch NZ1P...AS1
X
32
42
16
56
64
32
∅
18
74
7,3
5,3
∅5,3
15
30
±0,1
40
0
+1
100
22
M12x1
60
±0,1
3
0°
m
a
x.
45°
0°
+5°
M = 1,2 Nm
M = 1,2 Nm
Approach directions
Dog
X
59
66
∅
18
28 - 40,5 - 53 - 65,5 - 78
45°
0°
+5°
M12x1
M = 1,2 Nm
M = 1,2 Nm
Approach directions
PB = plastic roller (dimension X = 6 mm)
PS = steel roller (dimension X = 5 mm)
A
Operating point
B
End position
C
Reset point
ES538H
A
B
C
Contacts
open
closed
HB = plastic roller (dimension X = 6 mm)
HS = steel roller (dimension X = 5 mm)
Advertising