Safety information and Maintenance

(Part of the Operating Instructions for Safety System CET.-AS)

Correct Use

The safety switch CET.-AS is operated as a slave

on the safety bus AS-Interface Safety at Work and

functions as an electromagnetic interlock device

with guard locking.
In combination with a safety guard and the machine

control, this safety component prevents the safety

guard from being opened while a dangerous machine

movement is being performed.
For the control system, this means that

f

starting commands which cause hazardous situ-

ations must become active only when the safety

guard is in protective position and the guard lock-

ing is in locked position. The locked position of

the guard locking must be released only when the

hazardous situation is no longer present.

Before safety components are used, a risk as-

sessment must be performed on the machine in

accordance with

f

EN ISO 13849-1, Safety of machinery. Safety re-

lated parts of control systems. General principles

for design, Annex B

f

EN ISO 14121, Safety of machinery. Risk assess-

ment. Principles.

f

IEC 62061, Safety of machinery – Functional safety

of safety-related electrical, electronic and program-

mable electronic control systems.

Correct use includes compliance with the relevant re-

quirements for installation and operation, in particular

f

EN ISO 13849-1, Safety of machinery. Safety re-

lated parts of control systems. General principles

for design

f

EN 1088, Safety of machinery. Interlocking devices

associated with guards. Principles for design and

selection

f

EN 60 204-1, Safety of machinery. Electrical equip-

ment of machines. General requirements.

The safety switches are only allowed to be operated

in conjunction with the intended EUCHNER CET ac-

tuators. On the use of different actuators, EUCHNER

provides no warranty for safe function.
Important: The user is responsible for safe integra-

tion of the device in a safe overall system. For this

purpose the overall system must be validated, e.g.

in accordance with EN ISO 13849-2.
The permissible operating parameters must be ob-

served for correct use (see Technical data).
If a product data sheet is included with the product,

the information on the data sheet applies in case of

discrepancies with the operating instructions.
In the estimation of the PL for the overall system,

a maximum value of 100 years can be assumed

for the MTTF

d

according to the limit value in

EN ISO 13849-1:2008, Section 4.5.2. This cor-

responds to a minimum value for the PFH

d

of

2.47 x 10

-8

/h.

If the simplified method according to Section 6.3

of EN ISO 13849:2008-12 is used for validation,

the Performance Level (PL) might be reduced when

several devices are connected in series.

Exclusion of Liability and Warranty

In case of failure to comply with the conditions for

correct use stated above, or if the safety instructions

are not followed, or if any servicing is not performed

as required, liability will be excluded and the war-

ranty void.

General Safety Instructions

Safety switches fulfill personal protection functions.

Incorrect installation or tampering can lead to fatal

injuries to personnel.
Check the safe function of the safety guard par-

ticularly

f

after any setup work

f

after the replacement of a CET component

f

after an extended period without use

f

after every fault

Independent of these checks, the safe function of the

safety guard should be checked at suitable intervals

as part of the maintenance schedule.

Warning: Danger of fatal injury in the event of incor-

rect connection or incorrect use.
Safety switches must not be bypassed (bridging

of contacts), turned away, removed or otherwise

rendered ineffective. On this topic pay attention in

particular to the measures for reducing the possi-

bility of bypassing from EN 1088:1995+A2:2008,

section 5.7.
The device is only allowed to be installed and placed

in operation by authorized personnel

f

who are familiar with the correct handling of safety

components

f

who are familiar with the applicable EMC regula-

tions

f

who are familiar with the applicable regulations on

health and safety

f

who have read and understood the operating

instructions.

Prior to use, read the operating instructions on the

supplied CD/DVD, and keep them in a safe place.
Ensure the operating instructions are always avail-

able during mounting, setup and servicing.
EUCHNER cannot provide any warranty in relation to

the readability of the CD/DVD for the storage period

required. For this reason you should archive a printed

copy of the operating instructions. You can download

the operating instructions from www.EUCHNER.de.

Operating instructions on CD/DVD

Each device is supplied with operating instructions

on CD/DVD which contain detailed information on

the overall system. The following system require-

ments must be met to be able to display or print

the document:

f

PC with PDF Reader installed

f

CD/DVD drive

f

Opening and printing the documents

Important: the autoplay function for the drive must be

enabled (see operating system help) and you will need

a PDF Reader that can open PDF files from version 4.
1. Insert CD/DVD

¨

Selection table is opened in the browser

2. Click the related document for your system

¨

The document is opened and can be printed.

Mounting, setup and troubleshooting

The safety switch must not be opened.
The safety switch must be mounted with the

slide facing down or horizontal in order to

achieve safety category 4 in accordance with

EN 13849-1 for the safety guard position moni-

toring.

Assemble the safety switch so that

f

access to the switch is difficult for operating person-

nel when the safety guard is open

f

it is possible to operate the mechanical release and

check and replace the safety switch.

Safety switches and actuators must not be used

as an end stop.

Mount the safety switch only in assembled condi-

tion!

For detailed instructions on mounting, setup and

troubleshooting, please refer to the operating instruc-

tions on the CD/DVD.

Electrical Connection

For detailed information on the electrical connec-

tion, please refer to the operating instructions on

the CD/DVD.

Figure 1: AS-Interface M12 plug connector terminal

assignment

1

AS-Interface +

2

Auxiliary power 0 V

3

AS-Interface -

4

Auxiliary power 24 V

View of safety switch

plug connector

4

3

1

2

Advertising