EUCHNER CETx-AS) Benutzerhandbuch

Seite 4

Advertising
background image

EUCHNER GmbH + Co. KG Kohlhammerstraße 16 D-70771 Leinfelden-Echterdingen Tel. +49 711 7597-0 Fax +49 711 753316 [email protected] www.euchner.com

Safety information and Maintenance

(Part of the Operating Instructions for Safety System CET.-AS)

Inspection and Service

Danger! Loss of the safety function because of

damage to the system. In case of damage, the

related component must be replaced completely.

The replacement of individual parts of a component

(e. g. parts of the evaluation unit) is not allowed.

Regular inspection of the following is necessary to

ensure trouble-free long-term operation:

f

Check the switching function

f

Check the secure fastening of the devices and the

connections

f

Check for soiling

Check the safe function of the safety guard par-

ticularly

f

after any setup work

f

after the replacement of a CET component

f

after an extended period without use

f

after every fault

No servicing is required. Repairs to the device are only

allowed to be made by the manufacturer.

Subject to technical modifications; no r

esponsibility is accepted for the accuracy of this information. © EUCHNER GmbH + Co. KG 113769-02-10/13 (translation of the ori

ginal operating instructions)

Technical data

Parameter

Value

min.

typ.

max.

General
Material, slide

Stainless steel

Material, safety switch housing

Die-cast aluminum

Installation position

Any (recommendation: switch head downward)

Degree of protection

IP 67

Actuator approach speed, max.

20

m/min

Locking force F

max

6,500

N

Locking force F

Zh

in acc. with GS-ET-19

F

Zh

= F

max

/1.3 = 5,000

N

Weight

Approx. 1.0

kg

Degrees of freedom (actuator in recess) X, Y, Z

X, Y ± 5 mm; Z ± 4

mm

Connection type (depending on version)

Plug connector M12, 4-pin

Auxiliary voltage

24

V DC

-10%/+15%

Current consumption

50

mA

Current consumption solenoid I

CM

400

mA

Classification acc. to EN IEC 60947-5-3

PDF-M

AS-Interface data

EA code: 7

ID code: B

Total current consumption

-

-

30 mA

Valid AS-Interface addresses

1 - 31

AS-Interface inputs

Acc. to AS-Interface Safety at Work

Door monitoring contact

D0, D1

Solenoid monitoring contact

D2, D3

AS-Interface outputs
Guard solenoid

D0, 1 = Solenoid energized

Red LED

D1, 1 = LED on

Green LED

D2, 1 = LED on

Reliability values according to EN ISO

13849-1

Head downward or horizontal

Head upward

Category

4

3

Performance Level (PL)

e

e

PFH

d

3.1 x 10

-9

/ h

4.29 x 10

-8

/ h

Mission time

20

years

20

years

Advertising