Lenze 931ExK10 Benutzerhandbuch
Seite 34

34
MA 13.0001 DE-EN DE/EN 2.0
LED
Colour
State
Note
State
Green
on
The control is correctly supplied by a 24 V control voltage, the drive is
ready for operation.
blinking
Data is written on or read from the memory card.
off
No voltage
Power
Yellow
on
The power section is enabled, the motor is supplied with voltage. The
drive works with the set control.
off
The drive does not work, the output stage is inactive.
Error
Red
off
No fault
blinking
Internal drive error
1)
After the cause of the error has been eliminated, you have to
acknowledge the error message:
z
Either by using the parameterisation software, or via an edge at
DIN9 (controller enable).
z
If no error is active anymore, the LED goes out.
Green
Yellow
Red
on
z
The drive is in the initialisation phase after the control voltage has
been switched on.
z
A new firmware is being installed.
1)
Detailed description of the blink code: see Hardware Manual.
Note!
The light-emitting diode ”Error” constantly blinks if a fault is active:
ƒ
It only displays one fault at a time.
ƒ
If several faults are active at the same time, the fault that occured first is
displayed.