2 technical data, 1 general data and operating conditions, Technical data – Lenze 931ExK10 Benutzerhandbuch
Seite 42: General data and operating conditions, 2technical data

Technical data
General data and operating conditions
2
42
MA 13.0001 DE-EN DE/EN 2.0
2
Technical data
2.1
General data and operating conditions
Conformity
CE
Low-Voltage Directive 73/23/EEC
Regulations
EN 61800-3
Interference level B
Climatic conditions
Air humidity max. 90 % without condensation
Cooling
Passively via housing surface and rear panel
Permissible temperature ranges
Transport
-25 °C... +70 °C
Storage
-25 °C... +70 °C
Operation
0 °C ... +50 °C
above +40 °C, reduce the power by
20 W/°C
Permissible installation height
0 ... 1000 m amsl
above 1000 m amsl, reduce the rated
output current by 5 %/1000 m
Mounting position
Vertical
Mounting clearances
above/below
≥
100 mm
sidewise
Directly alignable
Monitoring
Overvoltage / undervoltage in the DC bus, overcurrent or
short circuit of the output stage, motor temperature and
output stage temperature, I
2x
t-monitoring of the motor,
encoder monitoring
Type of protection
IP 20
Inputs
6 digital inputs, 2 analog inputs
(adjustable via software)
Outputs
2 digital outputs, 2 analog outputs
(adjustable via software)
Bus system
CAN (DS301, DSP402)
Memory cards
Multimedia card