7 communication, 1 connection of digital frequency coupling at x10, Communication – Lenze 931ExK10 Benutzerhandbuch
Seite 55: Connection of digital frequency coupling at x10, Electrical installation
Advertising

Electrical installation
Communication
Connection of digital frequency coupling at X10
4
55
MA 13.0001 DE-EN DE/EN 2.0
4.7
Communication
4.7.1
Connection of digital frequency coupling at X10
Connection plan
B
B
GND
GND
GND
GND
Z
Z
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
A
A
X10
X10
< 15 m
A
A
B
B
Z
Z
A
A
B
Z
B
Z
931E-003.cdr
Fig. 6
Connection of digital frequency input and digital frequency output (X10)
X10 Slave drive
c
Signals with CW rotation
X10 Master drive
Cores twisted in pairs
Assignment of 9-pin Sub-D socket (X10) at the controller for digital frequency coupling
Pin
1
2
3
4
5
6
7
8
9
Signal
A
B
Z
GND
n. c.
A
B
Z
GND
0.14 mm
2
(AWG 26)
0.5 mm
2
(AWG 20)
0.14 mm
2
(AWG 26)
0.5 mm
2
(AWG 20)
0.14 mm
2
(AWG 26)
Advertising