Diaphragm Pumps PJ19424-726

Installation and connection

Translation of Original Operating- and Installation Instructions, english, KNF PJ19424-726 01/13

12

6. Installation and connection

Only install and operate the pumps under the operating parameters
and conditions described in Chapter 4, Technical data, and Section
2.3, Use in hazardous areas.

Observe the safety precautions (see Chapter 3).

6.1. Installation

Î

Before installation, store the pump at the installation location

for 3 hours to bring it up to room temperature.

Î

See Fig. 3 for the mounting dimensions.

Fig. 3: Mounting dimensions
(All dimensional tolerances conform to DIN ISO 2768-1, Tolerance
Class V)

WARNING

Danger of explosion from insufficient cooling

Î

Install the motor so that the motor fan can intake

sufficient cooling air.

Î

Ensure sufficient ventilation and heat dissipation

around the motor.

Î

Make sure that the installation location is dry and the pump is

protected against rain, splash, hose and drip water.

Î

Install the pump at the highest point in the system to prevent

condensate from collecting in the pump head.

Î

Protect the pump from dust.

Î

Protect the pump from vibrations and jolts.

Mounting dimensions

Cooling air supply

Installation location