9. Troubleshooting

DANGER

Extreme danger from electrical shock!

Î

Disconnect the motor power supply before working

on the motor.

Î

Make sure the motor is de-energized and secure.

1. Check the motor (see Tab. 11).

2. Also see the pump operating and installation instructions for

troubleshooting.

Tab. 8

Fault cannot be rectified

If you are unable to determine any of the specified causes, send
the motor to KNF Customer Service (see page 1 for the address).

If the motor is attached to a pump, observe the instructions for the
pump.

Fault
Motor
does
not
ramp up

Motor is
too
warm

Signifi-
cant
drop-off
in speed

Protec-
tion
device
trips

Possible Cause

Remedy

Load moment too high

Check motor and load
moment

Mains voltage too low

Check mains

Phase interruption

Check connection network

Faulty connection

Note wiring diagram and
motor type-plate

Overload

Compare motor type-plate
specifications

Switches too often

Verify rated operation
mode

Insufficient ventilation

Inspect ventilation paths,
check turn direction

Ventilation

paths

dirty Clean

Winding or terminal short
circuited

Measure isolation resis-
tance

Start time has been ex-
ceeded

Check start-up conditions