Diaphragm Pumps PJ19424-726

Servicing

Translation of Original Operating- and Installation Instructions, english, KNF PJ19424-726 01/13

18

8.3. Replacing molded diaphragm and valve plates

ƒ

Motor disconnected from mains and de-energized

ƒ

Pump free of dangerous substances

Spare part*

Position**

Quantity

Molded Diaphragm

(K)

1

Valve plate

(T)

2

Valve body

(F;G) identically

2 pieces in total

Sleeve (U)

2

O-ring (S)

2

* According to Spare parts list, chapter 10
** According to Fig. 4.

Tab. 12

Quantity Tools/Material
1

Allen key 4 mm

1

Screwdriver blade width 5.5 mm

1

Socket wrench 27 mm

1 Felt-tip

pen

Tab. 13

Î

Always replace the molded diaphragm, valve plates, valve

bodies, sleeves and O-rings together to maintain the pump
performance.

WARNING

Danger of explosion from generation of
explosive atmosphere!

Leaky connections can lead to dangerous explosive
atmospheres.

Î

Make sure that molded diaphragm, valve plates,

valve bodies, sleeves and O-rings are not dam-
aged, clean and properly installed.

Î

Check pneumatic pump connections for leaks.

Î

Work carefully when performing servicing.

Î

Replace defective parts immediately.

WARNING

Health hazard due to dangerous substances
in the pump!

Depending on the substance transferred, caustic
burns or poisoning are possible.

Î

Wear protective clothing if necessary, e.g.

protective gloves.

Î

Clean pump with suitable measures.

Conditions

Spare parts

Tools and material

Information on procedure