Electrical installation

EMC-compliant installation

Components in a CE-typical drive system

5

53

EDB712 DE/EN 2.1

5.2

EMC-compliant installation

Note!

The user is responsible for compliance with the EMC directive in the

machine application.

As a user you are compliant with the EMC directive if you follow the

chapter 5.2 ”EMC-compliant installation” during the electrical installation. In

this way you can be sure your drive system will not cause any EMC problems.
If all devices and system components comply with the CE requirement for

interference immunity in accordance with EN 50082-2, no electromagnetic

degradation is to be expected.

5.2.1

Components in a CE-typical drive system

Note!

Drive controller, RFI filter and mains choke are on a common

mounting plate.

System components

Specification

Drive controller

Voltage controller

RFI filter

66

Armature and field cable

Shielded power cable with tin-plated E-CU braid

with 85 % visual coverage.

Evaluated maximum length: 50 m

Mains cable between RFI filter and mains

choke as well as between mains choke and

drive controller

From cable length 200 mm:

Shielded power cable with tin-plated E-CU braid

with 85 % visual coverage

Motor cables

Shielded signal cable type LIYCY

Motor

Three-phase AC motor with resistive rotor

behaviour

Lenze type (series) ...L12, 10F4, 10F8, ...F12, ...S4,

11S6, ...S8, ...F8, 10F4, 11MF4 or similar