Electrical installation

EMC-compliant installation

Installation of a CE-typical drive system

5

54

EDB712 DE/EN 2.1

5.2.2

Installation of a CE-typical drive system

Note!

The EMC characteristics of a drive system are

installation-dependent. For this reason pay attention to the

instructions on filtering, shielding, earthing and layout.

Note!

If a different installation is used, e.g.

ƒ

usage of unshielded cables

ƒ

usage of common RFI filters instead of the specified RFI

filters

the machine or the system must be checked for compliance with

EMC limits for the assessment of conformity with the CE EMC

directive.

Filtering
RFI filters reduce high-frequency interference to a permissible level.

ƒ

Only use the RFI filter specified for the drive controller.

The selection of a suitable RFI filter is dependent on the load current:

Load current

Order designation

≤ 8 A

EZF3_008A002

≤ 10 A

EZF3_012A001

ƒ

Add further interference suppression measures if the motor cables are

longer than 50 m.

Advertising