Control terminals, Electrical installation – Lenze ELCAFHIxxx4E34NNER Highline Benutzerhandbuch

Seite 73

Advertising
background image

Electrical installation

Control terminals

4

l

73

EDKLCFH1134−EER DE/EN 1.0

4.6

Control terminals

Digital inputs

)

Note!

Total current at pin 1 of the connectors X41 ... X44: max. 500 mA.

X41 − Digital inputs DI1, DI2

Pin

Signal

Description

Data

Connector: female, 5−pin, M12

1

+24 V

Supply

2

Signal 2

DI2

HIGH

+13 .... 30 V DC

3

Gnd

Reference potential

LOW

0 ... +4 V

4

Signal 1

DI1

8 mA at 24 V DC

5

n. c.

Not assigned

X42 − Digital inputs DI3, DI4

Pin

Signal

Description

Data

Connector: female, 5−pin, M12

1

+24 V

Supply

2

Signal 2

DI4

HIGH

+13 .... 30 V DC

3

Gnd

Reference potential

LOW

0 ... +4 V

4

Signal 1

DI3

8 mA at 24 V DC

5

n. c.

Not assigned

X43 − Digital inputs DI5, DI6

Pin

Signal

Description

Data

Connector: female, 5−pin, M12

1

+24 V

Supply

2

Signal 2

DI6

HIGH

+13 .... 30 V DC

3

Gnd

Reference potential

LOW

0 ... +4 V

4

Signal 1

DI5

8 mA at 24 V DC

5

n. c.

Not assigned

X44 − Digital inputs DI7, DI8

Pin

Signal

Description

Data

Connector: female, 5−pin, M12

1

+24 V

Supply

2

Signal 2

DI8

HIGH

+13 .... 30 V DC

3

Gnd

Reference potential

LOW

0 ... +4 V

4

Signal 1

DI7

8 mA at 24 V DC

5

n. c.

Not assigned