Electrical installation – Lenze ELCAFHIxxx4E34NNER Highline Benutzerhandbuch

Seite 74

Advertising
background image

Electrical installation

Control terminals

4

l

74

EDKLCFH1134−EER DE/EN 1.0

Digital outputs

)

Note!

ƒ

Delay time between triggering and switching of the digital outputs: approx.
100 ms.

ƒ

If inductive loads are being connected, it is essential to use a spark
suppressor at the digital output.

X45 − Digital outputs DO1, DO2

Pin

Signal

Description

Data

Connector: female, 5−pin, M12

1

n. c.

Not assigned

2

Signal 2

DO2

HIGH

U

DC

at X11

3

Gnd

Reference potential

LOW

0 ... +4 V

4

Signal 1

DO1

Max. 500 mA per output

5

n. c.

Not assigned

X46 − Digital outputs DO3, DO4

Pin

Signal

Description

Data

Connector: female, 5−pin, M12

1

n. c.

Not assigned

2

Signal 2

DO4

HIGH

U

DC

at X11

3

Gnd

Reference potential

LOW

0 ... +4 V

4

Signal 1

DO3

Max. 500 mA per output

5

n. c.

Not assigned

Analog inputs, analog outputs

X51 − Analog inputs AI1, AI2

Pin

Signal

Description

Data

Connector: male, 4−pin, M12

1

AI1+

Analog input 1

2

AI1−

Analog input 1

3

AI2+

Analog input 2

4

AI2−

X52 − Analog outputs AO1, AO2

Pin

Signal

Description

Data

Connector: male, 4−pin, M12

1

AO1

Analog output 1

2

AO2

Analog output 2

3

GND

Reference potential

4

GND

Advertising