Torque, A1.104.01 rev. b double acting actuator (in.lb.), Double acting actuator torque (in.lb.) 90 – Emerson Process Management El-O-Matic E and P Series E25-E950 Benutzerhandbuch

Seite 10: Data sheet, Double acting torque

Advertising
background image

Data sheet

Sheet No.:
Date: January 2010

Copyright © Emerson Process Management. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website

www.El-O-Matic.com or from your nearest Valve Automation Center USA: +1 813 319 0266 Europe: +31 74 256 10 10 Asia-Pacific: +65 6501 4600

www.El-O-matic.com

A1.104.01 Rev. B

DOUBLE ACTING ACTUATOR TORQUE (In.lb.)

90°

Actuator

Torque of double acting actuators (in In.lb)

Supply pressure (psi)

Type Size

30

35

40

45

50

55

60

70

75

80

90

100

120

ED

12 43.9

51.4

58.9

66.4

73.9

81.4

88.9

104

111

119

134

149

179

ED

25 81.4

95.3

109

123

137

151

165

193

206

220

248

276

332

ED

40 153

179

205

231

257

283

309

361

387

413

466

518

622

ED

65 233

272

312

352

392

431

471

551

590

630

709

789

948

ED

100 344

402

461

520

578

637

696

813

872

930

1048

1165

1400

ED

150 551

645

739

833

927

1021

1115

1303

1397

1491

1680

1868

2244

ED

200 754

883

1011

1140

1269

1398

1527

1784

1913

2042

2299

2557

3072

ED

350 1310

1534

1757

1981

2205

2428

2652

3100

3323

3547

3994

4442

5337

ED

600 2226

2606

2986

3366

3747

4127

4507

5267

5647

6028

6788

7548

9069

ED

950 3323

3890

4458

5025

5593

6160

6728

7862

8430

8997

10132 11267 13537

ED

1600 5493

6431

7369

8307

9245

10183 11121 12998 13936 14874 16750 18626 22379

PD

2500 8774 10273 11825 13270 14768 16267 17847 20858 22363 23869 26880 29891 35912

PD

4000 14874 17414 19962 22495 25035 27576 30127 35210 37751 40293 45375 50458 60623

Note
1. Emerson Process Management recommends that the valve manufacturer supply the maximum required torque

values (Including any adjustments or suggested safety factors for valve service conditions or application).

Additionally, the valve manufacturer must identify at which position(s) and direction(s) of rotation

(Counter Clock Wise or Clock Wise) these maximum requirements occur.

2. If in doubt, or you require any assistance with sizing actuators, do not hesitate to contact your

nearest Emerson's Valve Automation Division representative.

3 Pressure on port "A" opens the actuator*
4 The actuator is shown in closed position*

(* code A, data sheet A1.503)

91.5°

-0.5°

91°

A

B

CLOSED

OPEN

Rotation

Start

End

Torque

DOUBLE ACTING TORQUE

Advertising
Dieses Handbuch ist für die folgenden Produkte bezogen werden: