The VFO Knob is of variable torque type. When the lever

at the left of the knob is set to NORM, the knob can be

rotated quickly because of the flywheel effect. When the

lever is set to TIGHT, the knob is given a heavy torque and

hence the knob will not rotate accidentally by external

shock. This feature is useful for fine tuning or mobile opera-

tion.

5-10 OPERATION OF 2 VFOs

The TS-780 has two VFO’s, A and B, each being con-

trolled by a microprocessor.

By using the FUNCTION switch, the desired VFO can be

selected. The use of two VFO’s also permits Operation with

their own frequencies (Cross channel Operation) such as

A-R or B-R Operation. The table below Shows the positions

of the FUNCTION switch and VFO’s selected.

The two VFO’s (A and BI can be operated in different

bands (for example, VFO A: 144 MHz, VFO B: 430 MHz;

or in the same band. They can also be used as a memory.

Examples:

1 .

2.

With your contact’s schedule frequency stored in VFO

B, you can operate VFO A until your contact Starts

transmitting.

During FM Operation, you can locate a sub-channel and

shift the frequency for repeater Operation by the VFO

not in use.

FUNCTION

SWITCH

RECEPTION

TRANSMISSION

Table 2

5-11 USE OF FM-CH

With the MODE switch set to FM-CH Position, the VFO

Operation changes to click type. In the OFF Position of the

F . S T E P s w i t c h , t h e c h a n n e l f r e q u e n c y s h i f t s u p i n

12.5 kHz Steps, and in the ON Position, in 5 kHz Steps.

4 3 3 . 0 0 0

4 3 3 . 0 0 5

4 3 3 . 0 1 2 5

4 3 3 . 0 1 0

4 3 3 . 0 2 5 0

4 3 3 . 0 1 5

4 3 3 . 0 3 7 5

4 3 3 . 0 2 0

4 3 3 . 9 8 7 5

433.995

When the MODE switch is changed to or from FM-CH

Position, the operating frequency becomes as shown table

3.

Frequency

145.317.7

145.317.6

145.315.0 145.315

displayed

145.312.5

145.315

145.315.0

(NOTE: "1)

(NOTE: '2)

Table 3

Note 1:

* 1

When the F. STEP switch is turned OFF, the frequency

will shift to the nearest 12.5 kHz step frequency

within the displayed frequency.

* 2 When the F. STEP switch is turned ON, the frequency

will shift the nearest 5 kHz step frequency within the

displayed frequency.

The 100 Hz digit disappears.

Note 2:

Table 3 Shows

the frequencies of VFO A. In the FM-CH

mode, the frequency of VFO B is shifted in the same way.

In the SSB mode, the frequency bellow

be changed.

5-12 USE OF F. STEP SWITCH

10 kHz Order may

This switch is used to Change the step of VFO frequen-

cy. By pressing the switch, the F. STEP LED will light. In

the SSB, CW or FM mode, this switch should be set to

OFF, except when the tuning knob is used. When the

switch is set to ON, the frequency on the 100 Hz Order

becomes even number and the frequency on the 10 kHz

Order is cleared to “0”. The frequency remains the same

when the switch is set to OFF.

Table 4

5-13 USE OF MEMORY

This switch is used to store the desired frequency in the

memory. The frequency is stored in the channels (1-1 0 ch)

by using the M switch and MEMORY selector. The stored

frequency is called out by pressing the MR switch to ON.