L 6 use of prio. m channel – Kenwood TS-780 Benutzerhandbuch

Seite 19

Advertising
background image

IO.5 MHz1

When the scan, starting from 431.637.5 MHz, reaches

the upper limit 431.987.5 MHz, it jumps down to the

lower limit 431.500.0 MHz where the scan is started

again. This action is repeated while holding 0.5 MHz

width.

(1 M H z ]

When the scan reaches from 431.637.5 MHz to the

upper limit 431.987.5 MHz, it jumps down to the lower

limit 431 .OOO.O MHz and reaches 431.987.5 MHz again.

This action is repeated while holding 1 MHz width.

[3 M H z ]

Similarly, when the scan reaches

from the lower limit

4 3 1 . 0 0 0 . 0 M H z t o t h e u p p e r l i m i t 4 3 1 . 6 3 7 . 5 M H z , i t

jumps down to the lower limit and reaches the upper limit

again. This action is repeated while holding 3 MHz width.

The lower limit is 431.637.5 MHz minus the frequency

on 100 kHz Order, and the upper limit is 433.987.5 MHz,

one step lower than 434.000.0 MHz which is the lower

limit plus 3 MHz but the scan Starts from 431.637.5 MHz.

[5 MHz1

The upper and lower limits are calculated in the same

manner as for 3 MHz width. The scan is repeated between

the lower limit and the upper limit while holding 5 MHz

width.

[lO MHz]

The scan i s r e p e a t e d b e t w e e n t h e u p p e r l i m i t

4 3 9 . 9 8 7 . 5 M H z a n d t h e l o w e r l i m i t 4 3 0 . 0 0 0 . 0 M H z

while holding 10 MHz width.

4 3 0

4 3 1

432

4 3 3

4 3 8

4 3 3

440

S C A N
.w
switch

I

I,

432.967.5

Note 1: In the SCAN W Position 3, 5 or 10, the scan in the

144 MHz band is repeated between the upper

l i m i t 1 4 5 . 9 8 7 . 5 M H z a n d t h e l o w e r l i m i t

1 4 4 . 0 0 0 . 0 M H z .

Note 2: In these Position, the scan does not shift over the

144 and 430 MHz bands. For example, when the

SCAN W is 5 in 438.250.0 MHz, the scan is ef-

fected holding 5 MHz width.

Note 3: The scan width should be calculated even in the

following cases:

1) When VFO (A, B) is switched.

2) When SCAN W switch is set to another posi-

tion.

3) When BAND switch is depressed.

Note 4: The scan w i d t h r e m a i n s unchanged w h e n t h e

SCAN switch is depressed for BUSY stop.

To Change the scan width, the scan should be

released.

Note 5: The BAND switch can be used during scan opera-

tion, but it does not function continuously when it

is kept depressed. This switch also functions even

when the F. LOCK switch is ON.

The scan is released when the PRIO. M, MR or MS switch is

set to ON.

5-15 USE OF MS (MEMORY SCAN) SWITCH

When the 144 MS or 430 MS switch is set to ON, the

function (CH No.) flickers t o i n d i c a t e t h a t t h e m e m o r y

channels (l-l 0 ch) can be scanned (the squelch threshold

should be set as in the case of VFO scan).

With the 144 MS switch ON, the memory channel for

144 MHz band can be scanned. With the 430 MS switch

ON, the memory channel for the 430 MHz band is scann-

ed. When both switches are ON, all the channels (both for

144 and 430 MHz bands) are scanned. To hold the scan,

use the procedure for VFO scan. To restart the scan, set

the SCAN switch to ON.

Note 1: Scan is not effected when the SCAN switch is

kept depressed.

Note 2: When scan is held in the ON Position of both MS

switches, it can be restarted by setting either

switch to OFF or by pressing the CALL or MR

switch.

Note 3: When all the channels are 144 MHz band and the

430 MS switch is set to ON, the function flickers

q u i c k l y a n d a oscillation Sound i s h e a r d con-

tinuously. This also occurs when all the channels

are 430 MHz band and the 144 MS switch is set

to ON.

Note 4: Only memorized channels are scanned.

5-l 6 USE OF PRIO. M CHANNEL

With the PRIO. M 9 or 10 switch set to ON, stored fre-

quencies in the memory channels 9 or 10 can be recalled

with first priority. In the channel 9 and 10.

145.000.0 MHz and 433.000.0 MHz are preset respec-

tively, while any frequency can be memorized in each

channel. Display of the PRIO. M channel is as follows:

c

o

r

c

Note: 1 The PRIO. M 9 is Prior to the PRIO. M 10.

Note: 2 The PRIO. M channel frequency is displayed to

100 Hz digit.

5-17 BACKUP OF MEMORY CHANNEL FRE-

QUENCY

Any desired memory channel frequency can be stored in

t h e R A M ( R a n d o m A c c e s s M e m o r y ) o f t h e micro-

Computer. But the data (frequency) in the RAM is cleared

when the power switch is set to OFF. The transceiver has

its own built-in backup circuit to hold the data (frequency)

even when the power switch is OFF during both AC and DC

operations. By loading backup battery in the transceiver

battery case, the battery power is always supplied to the

backup c i r c u i t . I n t h i s w a y , t h e d a t a i s n o t . c l e a r e d

regardless of the Position of the power switch. The backup

18

Advertising