With the RIT switch ON, the RIT knob allows the Operator

to vary the receive frequency by about

1.5 kHz without

affecting the transmit frequency. The Center Position “0”

is RIT-OFF.

2 6 R I T C o n t r o l

3 6 M . S Switch

This switch selects and scans the frequency stored in the

memory channel. Scan is released by the HOLD switch or

by setting the transceiver in transmit mode.

2 7 IF SHIFT Knob

By using this control, the IF crystal filter Center frequency

can be shifted

1 kHz, allowing adjustment of tone quali-

ty, or eliminating interference from adjacent frequencies.

For normal Operation, this control should be set to the

Center “ 0 ” Position (detent).

28 SQUELCH Control

T u r n i n g t h i s c o n t r o l c l o c k w i s e during F M m o d e w i l l

activate the squelch circuit.

2 9 S C A N - W

This switch is used to select the scan width (0.5, 1, 3, 5

and 10 MHz).

30 AF GAIN Control

This control adjusts the gain of the receiver audio amplifier.

Clockwise rotation will increase the output level

31 RF GAIN Control

For adjusting the RF amplifier gain of the receiver. The gain

is minimum at the extreme counterclockwise Position. Nor-

mally, this control is set in its extreme clockwise Position.

3 2 F . S T E P Switch

By using this switch, the VFO frequency is varied at a slow

or fast Speed as shown below. The operating conditions

can be checked on the F. STEP indicator.

F . S T E P

O F F

O N

SSB.CW,FM

20 Hz

200 Hz

FM

CH

12.5 kHz

5 kHz

1

3 3 R I T Switch

This push switch turns the RIT (Receiver Increment Tuning)

circuit ON and OFF. With the switch depressed, the circuit

is activated and the RIT indicator is illuminated. The RIT cir-

cuit is turned OFF when the switch is out.

3 4 S C A N Switch

This switch turns ON and OFF the VFO scan circuit. The

VFO frequency is scanned at the Speed selected by the

F. STEP switch. The switch is also used for re-scanning of

M. S (memory scan) or for scanning at busy stop.

3 5 H O L D

This switch is used to stop scan Operation.

3 7 B A N D Switch

For selecting the band (144-145 MHz or 430-439

MHz)

to be operated. By pressing the UP switch, the frequency is

stepped up band by band. When the DOWN switch is

pressed, the frequency is stepped down band by band. In

either case, the band is switched in 1 MHz Steps.

3 8 M ( M e m o r y ) Switch

This switch is used to store the desired frequency in the

memory channel.

When the switch is depressed, an oscillation Sound is

h e a r d , i n d i c a t i n g t h a t t h e f r e q u e n c y i s s t o r e d i n t h e

memory channel.

3 9 F . L O C K Switch

This switch locks the operating frequency of VFO. With the

switch ON, the VFO frequency remains unchanged even

when the tuning knob, BAND switch or MIC UP/DOWN

s w i t c h i s m a n i p u l a t e d . T h i s f e a t u r e i s u s e f u l w h e n

operating the transceiver on the same frequency for many

hours, or when it is used for mobile Operation.

The RIT switch can be used even in the ON Position of the

F. LOCK switch. The F. LOCK indicator will light when the

F. LOCK switch is ON.

4 0 M . R ( M e m o r y Recalll Switch

Memory channel is called out when this switch is turned

ON. For the channels in which frequencies are not stored,

the corresponding channel numbers are indicated.

3-2. REAR PANEL

1

430 MHz ANT (antenna) Connector IN type)

For connection of the 430 MHz band antenna.

2

144 MHz ANT (antenna) Connector (M type)

For connection of the 144 MHz band antenna.

3 H e a t S i n k

Dissipates heat from the final Stage transistors and power

supply transistors.

4 C W K E Y Jack

This jack is used for operating the transceiver in CW mode.

Connect a telegraph key using a 2P plug.

5

SP (Extemal Speaker) Jack

Connect an external speaker of 4-8 ohms impedance using

the supplied plug.

7

Advertising