14 use of scan switch – Kenwood TS-780 Benutzerhandbuch

Seite 18

Advertising
background image

1 S e l e c t t h e d e s i r e d frequen-

cy by the tuning knob.

2 S e l e c t t h e d e s i r e d c h a n n e l

by the MEMORY selector to
store the frequency.

3 D e p r e s s t h e M R s w i t c h to

ensure t h a t t h e s e l e c t e d

4 D e p r e s s t h e M s w i t c h a n d

memory.

Fig. 14 Use of MEMORY

Fig. 15 MEMORY Recall

L

The channels (9, 10) are for PRIO. M channels. In the

9 c h , 1 4 5 . 0 0 0 . 0 M H z i s s t o r e d a n d , i n t h e 1 0 c h ,

4 3 3 . 0 0 0 . 0 M H z i s s t o r e d . T h e s e f r e q u e n c i e s can be

changed as desired. In this case, the PRIO. M channels (9,

IO) are also changed.

Note 1: The PRIO. M channels (9, IO) are the same as the

channels (9, IO) called out by the MR switch.

Note 2: When an empty channel is called out, only the

channel No. is indicated on the display.

Note 3: When the channels (9, IO) are called out by the

MR switch, the channel No. is indicated as"C, C ‘!

N o t e 4 : W h e n a f r e q u e n c y , s t o r e d i n O N Position of

F. STEP switch, is called out, the F. STEP LED

will light.

Note 5: Frequency down to 10 Hz Order is stored, but the

frequency Change due to RIT is not stored.

Note 6: In the FM-CH mode, the frequencies on the 1 kHz-

10 Hz Order are stored as “0”. When called out,

the full frequency is indicated on the display.

Note 7: In repeater Operation, when a frequency is stored

during transmission, only the frequency which is

not shifted is stored.

SCAN
W
switch

430

431 431.5 432

433

434

436

440

r

0.5

3

5

IO

433.981.5

- - - - - - -

439.987.:

5-14 USE OF SCAN SWITCH

W i t h t h e S C A N s w i t c h O N , t h e F U N C T I O N (A, b)

flickers to indicate that the frequency is scanned.

FM-CH mode

1. Adjust the squelch sensitivity by the SQL VR and set the

Signal level for BUSY stop.

2. By setting the SCAN switch to ON, the channel is

shifted to the next one regardless whether a Signal is

present in the channel (If the switch is kept depressed,

the channel is not shifted).

3. Even when the channel is BUSY stopped, the function

keeps flickering.

4. When Signal is absent in the BUSY stop channel, the

SCAN Stops for about 1 seconds and Starts again.

FM mode

1. Depress the SCAN switch continuously and the channel

is scanned at a high Speed. In BUSY stop, keep the

switch depressed to fast forward the Signal beyond the

r e c e i v i n g b a n d . I n t h i s w a y , t h e scan i s r e s t a r t e d

smoothly.

2. Other operations are the same as in the FM-CH mode.

Other modes

1. Search Operation only; BUSY stop is not used.

Depress the HOLD switch or transmit Signals.

The scan

is released and the FUNCTION Stops flickering.

Use of SCAN W Switch

The SCAN W switch is used to adjust the scan width.

The scan width is changed according to the frequency at

the Start of scan. The following Shows

the Operation of the

SCAN W switch in the FM-CH mode where the frequency

is scanned starting from 431.637.5 MHz.

430 431 .637.5

440

Fig. 16

17