M&C TechGroup MP47 Ex Operator's manual Benutzerhandbuch
Seite 46

Diaphragm Pumps PJ19424-726
Servicing
Translation of Original Operating- and Installation Instructions, english, KNF PJ19424-726 01/13
18
8.3. Replacing molded diaphragm and valve plates
Motor disconnected from mains and de-energized
Pump free of dangerous substances
Spare part*
Position**
Quantity
Molded Diaphragm
(K)
1
Valve plate
(T)
2
Valve body
(F;G) identically
2 pieces in total
Sleeve (U)
2
O-ring (S)
2
* According to Spare parts list, chapter 10
** According to Fig. 4.
Tab. 12
Quantity Tools/Material
1
Allen key 4 mm
1
Screwdriver blade width 5.5 mm
1
Socket wrench 27 mm
1 Felt-tip
pen
Tab. 13
Î
Always replace the molded diaphragm, valve plates, valve
bodies, sleeves and O-rings together to maintain the pump
performance.
WARNING
Danger of explosion from generation of
explosive atmosphere!
Leaky connections can lead to dangerous explosive
atmospheres.
Î
Make sure that molded diaphragm, valve plates,
valve bodies, sleeves and O-rings are not dam-
aged, clean and properly installed.
Î
Check pneumatic pump connections for leaks.
Î
Work carefully when performing servicing.
Î
Replace defective parts immediately.
WARNING
Health hazard due to dangerous substances
in the pump!
Depending on the substance transferred, caustic
burns or poisoning are possible.
Î
Wear protective clothing if necessary, e.g.
protective gloves.
Î
Clean pump with suitable measures.
Conditions
Spare parts
Tools and material
Information on procedure