IMP Pumps NMT(D) LAN (C) 40-100 & NMT SAN LAN (C) flanges Benutzerhandbuch

Seite 26

Advertising
background image

-26-

GB

Markings

Descriptions

L

230 VAC, electricity power supply

N

PE

Safety ground

FC

Ferrite core for High frequencies interfaces compliance.

PE, L and N wires should be lead through it (part is in the

package with the cable glands).

The pump has a built-in over current fuse and protection, temperature

protection and basic overvoltage protection. It doesn’t need an additional

thermal protection switch. Connection leads should be capable of carrying

rated power and should be properly fused. Ground lead connection is

essential for safety. It should be connected first. Grounding is only meant for

pump safety. Pipes should be grounded separately.

• Connection of the pump must be carried out by qualified

personnel,

• Connection of the connecting cable must be done in a

manner that ensures it is never in contact with the casing

of the device, due to the high temperatures of the casing,

• The device should not be used by children and persons with

reduced physical, sensory or mental abilities, or with lack

of experience or knowledge, unless they are supervised

or instructed on the use by a person responsible for their

safety,

• Children should always be supervised to prevent playing

with the device.

4.3

Communication installation

4.3.1 Digital inputs

Marking

Function

IO1

Integrated pull up resistor. Input is “ON” when not

connected and “OFF” when connected to 0V.

IO2

Input is “ON” when connected to >8V (pump power

supply can be used)

4.3.2 Relay output

Markings

Description

NC

Normally closed relay contact

NO

Normally opened relay contact

C

Common relay lead