GB

6

Error and Troubleshooting

If pump failure occurs, the error causing the failure will appear in the display

screen.

Errors on the screen are identified as:

E X Y

E

Error marking

X

Error group

Y

Service code

Error

group (X)

Error

description

Possible cause and solution

1

Low load

detected

There is no medium in the pump. Check if

there is medium in the system.

2

Motor overload

Excessive current load or blocked rotor.

If the issue persists, check if the rotor is

spinning freely.

3

Motor too hot

Motor has exceeded allowed temperature

and is now stopped to cool down. Once

cooled, it will automatically restart.

4

Electronics error

An electronics error was detected.

The pump can still operate, but needs

servicing.

5

Motor/stator

failure

There could be an interruption in the motor

winding. Pump needs servicing.

The

service code (Y) is intended for service personal.

If the pump is unresponsive, disconnect and connect it back to the electrical

grid.