4.3.3 Ethernet
In order to use various web tools, the pump should be connected to network

or a personal computer over Ethernet plug. Use CAT-4 or better network

cable connected to “PATCH” configuration if plugged into a network or wired

as “CROSSOVER” for connection to PC.

»Crossover cable wire configuration

Patch cable wire configuration

When the pump is connected to network or another computer, it can be

reached by typing its IP address or NetBIOS name into browsers address

line. Default IP address is

192.168.0.245 and default NetBIOS name is

»

nmtpump«.

• If more than one pump will be connected into network, each

individual pump should have its IP address and NetBIOS

name changed and noted. That will prevent network

collisions and provide naming service in relation to pump

function.

• To achieve pump IP protection, network cable should

be lead over the inlet and then crimped to a connector.

Ethernet plug is galvanicaly insulated, but the rest of the

cabling could still present shock hazard. All connections

should be made with the power turned off.

4.3.3.1 Twin pump connection
Both pumps are interconnected with a cross-over network cable. If you wish

to connect the pumps to a local network, replace the network cable with

two connections to the nearest network switch. The left pump has the same

network settings as an individual pump. NetBIOS name is »

nmtpump« and IP

address is

192.168.0.245. Right pump netBIOS name is set to »nmtpump2«

and IP address is

192.168.0.246. On the »Network« page, »Twin mode with

IP:« field assigns Twin IP address. Left pump has the IP address of the

right pump in this field, while the right pump has the address of the left one.