If you need to change the IP address of the pump because you want to

network multiple pumps, make sure you also enter the new address into the

connected twin pump.

• Single pumps can also work in alternating mode if you

connect and set them in a way outlined in the previous

paragraph.

• Both pumps start when power is applied and settle for

priority with the help of a random number. The operating

time is thus equally shared even if the power is often

interrupted.

5

Setup and operation

5.1

Control and functions

The pump can be controlled by display panel, digital inputs or Ethernet

connection.

• Display panel controls and overviews pump modes, parameters and

on/off,

• Digital inputs control basic pump operation (run, stop, maximum

set…),

• Relay output can signal pump status,

• Ethernet connections offers control over all pump functions and

settings (pump variables, digital inputs, error overview).

Several signals will influence the pump operation. For this reason, settings

have priorities as shown in the table below. If two or more functions are

active at the same time, the one with highest priority will take precedence.

Priority

Pump control panel and

Ethernet settings

External signals

1

Stop (OFF)

2

Max RPM (Hi)

3

Stop (Run not active)

4

Max.

5

Setpoint setting