Dvi/rgb output choosing the correct output mode – WolfVision VZ-C32 User Manual Benutzerhandbuch

Seite 16

Advertising
background image

DVI/RGB Output

Choosing the Correct Output Mode

14

The DVI and RGB outputs (#16, #18, #23 and #24) can output signals in following formats:

- VGA

(4:3 - 640x480 pixels) at 60Hz

- SVGA

(4:3 - 800x600 pixels) at 60Hz, 75Hz or 85Hz

- XGA

(4:3 - 1024x768 pixels) at 60Hz, 75Hz or 85Hz
- native image on VZ-C32

- SXGA-

(4:3 - 1280x960 pixels) at 60Hz or 85Hz
- native image on VZ-C12²

- SXGA

(

- 1280x1024 pixels) at 60Hz or 75Hz

- SXGA+

(4:3 - 1400x1050 pixels) at 60Hz or 75Hz

- UXGA

(4:3 - 1600x1200 pixels) at 60Hz

- XGA 16:9

(special format for non-HDTV capable 16:9-Plasma displays) at 60Hz

- WXGA/60

(16:9 Widescreen - 1360x768 pixels) at 60Hz

- WSXGA+/60 (16:10 Widescreen - 1680x1050 pixels) at 60Hz
- 720p

(16:9 Widescreen HD/HDTV - 1280x720 pixels) at 50Hz or 60 Hz
- native image on VZ-C12²

- 1080p

(16:9 Widescreen HD/HDTV - 1920x1080 pixels) at 50Hz or 60Hz

Please note that the Visualizer can not check the possible resolution, if the

connected units or the cables* are not "Plug and Play" compatible. If the Visualizer can not
detect the resolution of the connected device, the output is set to the default of

SXGA-/60Hz VZ-C12².

(*Cables with plug and play compatibility must have a 15-pin plug on both ends with all pins connected, pin 9 is not
used).

If you can not use the "Auto resolution" function, you can select the output mode manually in
the on-screen menu of the Visualizer (see page 16).

In order to achieve the best picture quality you must set the outputs of the Visualizer to
match the native resolution of your display unit (e.g. LCD or DLP projector or monitor).
Important: What matters is the native resolution of the projector or monitor, not the maximum
resolution that it can display (in compressed mode). The native resolution is the actual
number of pixels of the built-in LCD display or DLP chip of a projector or monitor. Most LCD
or DLP projectors can also display higher resolutions than their native resolution, but only in
compressed mode and with inferior picture quality.
Do NOT set the output of the Visualizer to a higher standard than the native resolution
of your display unit!

If you output the Visualizer image on a CRT monitor or CRT projector, use an output mode
with 75 or 85Hz, because 60Hz may show a slight image flickering. For LCD/DLP projectors
or monitors and video conferencing units 60Hz is the best choice. If you are unsure what the
best mode is, read the user manual of the connected units.

Do not set a higher refresh rate than your monitor or projector can display, otherwise
the monitor or projector can be damaged!
Follow the instructions in the user manual of the connected units.

Please note, if 4:3 and 16:9 or 16:10 resolutions are used simultaneously, the 4:3 display
shows black bars on top and bottom. This is necessary to ensure that all displays show
the same image content.

5:4

The "Auto resolution" function is activated by default. In this mode the Visualizer
continuously checks which devices are connected to the RGB (#16, #18 and #24) and DVI
output (#23) and automatically sets the optimal output mode for each connected device
separately.

XGA /60Hz

on VZ-C32 and

Advertising