MAINTENANCE

17

1. Turn the unit off (#12) and disconnect the power cord (#15)!
2. Press the release button and swing the unit downwards. (see figure 1 and figure 2)
3. Release the quick lock by turning and lift up the lid. (see figure 2)
4.

Change the lamp (or both lamps) (see figure 3)

5. To swing the unit up, release the security lock mechanism, by pulling and turning

counterclockwise. (see figure 2)

CAUTION: LAMP CAN BE HOT!

Lamp type:

Halogen long life lamp 24V/150W at 300 h average burning life.
WolfVision part no.: 100814

Before changing the lamp allow it to cool or use a cloth to avoid burning fingers!
When inserting a new lamp into the socket use a cloth to prevent fingerprints on the lamp!

figure 1

release button

Exchanging Lamps

figure 3

figure 2

security lock

mechanism

quick

lock

LOCKED

pull

and

turn

to

unlock

UNLOCKED

CAUTION!

Pinch Point!

Disconnect the power cord (#15) before changing the fuses!
The fuses (#14) are situated behind a small lid at the power socket.
It can easily be opened with a small screwdriver etc.
Remove the socket, exchange the fuse(s) carefully,
and put back the socket the right way round into the socket holder.

The type of fuse is: T 3,15A. Do not use any other type !

Change the fuses for new ones and switch the unit on.
If the fuse fails again contact your Visualizer dealer!

Exchanging Fuses