DVI-I Port

1 - T.M.D.S. Data2-

9 - T.M.D.S. Data1-

17 - T.M.D.S. Data0-

2 - T.M.D.S. Data2+

10 - T.M.D.S. Data1+

18 - T.M.D.S. Data0+

3 - T.M.D.S. Data2/4 Shield

11 - T.M.D.S. Data1/3 Shield

18 - T.M.D.S. Data0+

4 - T.M.D.S. Data4- (*)

12 - T.M.D.S. Data3- (*)

19 - T.M.D.S. Data0/5 Shield

5 - T.M.D.S. Data4+(*)

13 - T.M.D.S. Data3+ (*)

20 - T.M.D.S. Data5- (*)

6 - DDC Clock

14 - +5V Power

21 - T.M.D.S. Data5+ (*)

7 - DDC Data

15 - Ground (return for +5V,

22 - T.M.D.S. Clock+

8 - Analog Vertical Sync

HSync and Vsync)

23 - T.M.D.S. Clock-

C1 - Analog Red

16 - Hot Plug Detect

24 - Analog Vertical Sync

C4 - Analog Horizontal Sync

C2 - Analog Green

C3 - Analog Blue

C5 - Analog Ground

*...not used

(analog R, G & B return)

m

Pin 24

Pin 8

Pin 1

Pin 9

Pin 17

C4

C1

C2

C3

C5

15

The Ceiling Visualizer is fitted with an automatic lamp changer.
If one lamp fails, there is no need to replace it immediately, as the automatic lamp changer
automatically switches to the second (spare) lamp. When the unit changes lamps there is
an on-screen message saying: "Changing lamp".
When switching on the unit the Visualizer checks if both lamps are working. If one lamp fails
there will be an on screen message for a couple of seconds displaying "Lamp x blown".
This prevents a user from forgetting to change a defective lamp.

Automatic Lamp Changer

If the unit gets too hot (improper ventilation or air extraction) a built in thermostat will switch
off the light of the Visualizer. Verify that proper ventilation and air extraction is available and
allow the unit to cool.

Thermostat

In some rooms the 3 built-in infrared receivers of the Ceiling Visualizer may not be enough.
In this case connect the supplied external infrared receiver to the IR-sensor plug (#17) and
position the IR-sensor somewhere on the ceiling (or in the room) where the users normally
point the remote control at.

IMPORTANT

External Infrared (IR) Sensor

Lightbox (optional)

When a lightbox is used, the top light of the Visualizer should be switched off
with the assigned PRESET key (LIGHT).
Using a bottom light has the disadvantage that the Synchronized Lightfield of the top light
no longer marks the pick-up area of the built-in camera.

The recommended lightbox for the Ceiling Visualizer is the WolfVision Lightbox LB-38.