11116552.07 GB/D 06/2010

10

WIKA Operating instructions/Betriebsanleitung E-10, E-11

11116552.07 GB/D 06/2010

11

WIKA Operating instructions/Betriebsanleitung E-10, E-11

Specifications

Model E-10 / E-11

Pressure ranges

bar

0.4

0.6

1

1.6 2.5

4

6

10 16

25

Over pressure safety

bar

2

4

5

10

10

17

35

35 80

50

Burst pressure

bar

2.4

4.8

6

12

12

20.5 42

42 96

96

Pressure ranges

bar

40

60

100 160 250 400

600

1000

1)

Over pressure safety

bar

80

120 200 320 500 800

1200

1500

Burst pressure

bar

400 550 800 1000 1200 1700

2)

2400

2)

3000

{Vacuum, gauge pressure, compound range, absolute pressure are available}

1)

Only Model E-10.

2)

For model E-11: the value specified in the table applies only when sealing is

realised with the sealing ring underneath the hex. Otherwise max. 1500 bar applies.

Materials

„

Wetted parts

(other materials see WIKA diaphragm seal program)

»

Model E-10

Stainless steel (> 25 bar stainless steel and Elgiloy

®

)

»

Model E-11

Stainless steel
O-ring: NBR {FPM/FKM}

„

Case

Stainless steel

Internal transmission fluid

Synthetic oil (not for model E-10 with pressure ranges > 25 bar)

Specifications

Model E-10 / E-11

Power supply U+

DC 10

... 30 V with signal output 4 ... 20 mA, 2-wire

DC 6 ...

30 V with signal output 1 ... 5 V, 3-wire

Signal output and

R

A

in Ohm

4 ... 20 mA, 2-wire R

A

≤ (U+ - 10 V) / 0.02 A

maximum ohmic load R

A

1 ... 5 V, 3-wire, R

A

> 10000

Response time (10 ... 90 %)

ms

1 (< 10 ms at medium temperatures below -30 °C for pressure

ranges up to 25 bar or with flush diaphragm)

Insulation voltage

DC 500 V

Accuracy

% of span

0.25

(BFSL)

0.5

3)

3)

Including non-linearity, hysteresis, zero point and full scale error (corresponds to

error of measurement per IEC 61298-2).
Adjusted in vertical mounting position with lower pressure connection.

Non-linearity

% of span

0.2

(BFSL) according to IEC 61298-2

Non-repeatability

% of span

0.1

1-year stability

% of span

0.2

(at reference conditions)

Permissible temperature of
Medium

-40 ... +105 °C / -40 ... +221 °F

Ambience

°C

T6: -40 ... +60 °C

T5: -40 ... +75°C

T4 ... T1: -40 ... +105 °C

Ambience

°F

T6: -40 ... +140 °F

T5: -40 ... +167°F

T4 ... T1: -40 ... +221°F

Storage

-40 ... +105 °C /-40 ... +221 °F

Rated temperature range

0 ... +80 °C / +32 ... +176 °F

Temperature coefficients within

rated temperature range

„

Mean TC of zero

% of span

0.2 / 10 K

„

Mean TC of range

% of span

0.2 / 10 K

CE- conformitiy

„

Pressure equipment directive

This instrument is a pressure accessory as defined by the directive

97/23/EC

7. Starting, operation

GB

Cable

with 2 m length

IP 67

3-wire

2-wire

7. Starting, operation

GB

red

red

black

black

brown

screen/case