Starting, operation gb – WIKA WUC-16 Benutzerhandbuch

Seite 13

Advertising
background image

11384850.07 GB/D 06/2014

WIKA Operating instructions / Betriebsanleitung WUC-1x

13

Wiring details

Bayonet connector,
4-pin

Circular connector M12x1, 4-pin

Flying leads,
1.5 m

2-wire

U+ = A

U- = D

U+ = 1

U- = 3

U+ = red

U- = black

3-wire

U+ = A

U- = D

S+ = B

U+ = 1

U- = 3

S+ = 4

U+ = red

U- = black

S+ = brown

Wire gauge

-

-

0.22 mm

2

(AWG 24)

Diameter of cable

-

-

4.8 mm

Torque required
for mounting counter-
connector should be
ensured:

1 Nm

1 Nm

-

Ingress protection
per IEC 60529

IP 67 (NEMA 4)

IP 67 (NEMA 4)

IP 67 (NEMA 4)

The ingress protection classes specified only apply while the pressure transmitter is connected with female connectors

that provide the corresponding ingress protection.

Refer to remark for IP-protection at clause 7 “Specific conditions for safe use in explosive atmosphere”

7. Starting, operation

GB

Current for external display- or evaluation equipment can be supplied directly from the circuit, when operating a transducer

with current output. A voltage drop specific to the display unit is to be considered. The UHP-display unit of type WUR-1 has a

specific voltage drop of 6 V. The transducers are short-circuit-proof for a short time, but anyhow any incorrect connection of

the instrument should be avoided.

4

3

1

2

Advertising