Starting, operation gb – WIKA WUC-16 Benutzerhandbuch

Seite 15

Advertising
background image

11384850.07 GB/D 06/2014

WIKA Operating instructions / Betriebsanleitung WUC-1x

15

Specifications

Models WUC-10, WUC-15 and WUC-16

WUC-10 / WUC-15

WUC-16

Pressure ranges

psi

30

60

100

160

250

350

500

1000

1500

bar

2

4

7

11

17

25

36

70

100

Over pressure safety

1)

psi

120

120

210

320

500

750

1100

2100

3000

Burst pressure

1)

psi

1800

1800

2200

2600

4800

6200

7400

8000

10500

Pressure ranges

psi

2000

3000

5000

bar

145

225

360

Over pressure safety

1)

psi

4200

6600

10000

Burst pressure

1)

psi

10500

10500

10500

Other pressure ranges and pressure units (e.g. MPa, kg/cm

2

) on request

Measuring principle

Metal thin-film sensor

Materials
Wetted parts

Pressure connection

316L VIM/VAR

Pressure sensor

2.4711 / UNS R30003

Case

304 SS

Particle test

≤ 0.1 µm Particle 0.1 ptc / ft³ according to Semi E49.8

Inboard helium leak test

< 1 x 10

-9

mbar l/sec (atm STD cc/sec) according to Semi F1

Surface finish

Electropolished, average Ra ≤ 0.13 µm (RA 5); max. Ra ≤ 0.18 µm (RA 7) exceeds Semi F19

Dead volume

cm

3

WUC-10 < 1.5, WUC-15 < 1, WUC-16 < 1

Permissible Medium

Special gas / Vapour / Liquid

Power supply U+

U+ in VDC

10 ... 30 with output signal 4 ... 20 mA / 0 ... 5 V

14 ... 30 with output signal 0 ... 10 V

Signal output and maximum

ohmic load R

A

R

A

in Ohm

4 … 20 mA, 2-wire

R

A

≤ (U+ – 10 V) / 0.02 A

0 ... 5 V, 3-wire

R

A

> 5 k

0 ... 10 V, 3-wire

R

A

> 10 k

1) 1 psi = 0.069 bar

7. Starting, operation

GB

Advertising
Dieses Handbuch ist für die folgenden Produkte bezogen werden: