The sum of the values of the connected sensor and the connecting

cables used must not exceed the following values for the maximum

permissible capacitance and inductance:

Model T24.10.xx2

II 1G EEx ia Group IIB

C

sensor

+ C

cable

< C

O

C

O

= 500 µF

L

sensor

+ L

cable

< L

O

L

O

= 50 mH

Model T24.10.xx2

II 1G EEx ia Group IIC

C

sensor

+ C

cable

< C

O

C

O

= 20 µF

L

sensor

+ L

cable

< L

O

L

O

= 10 mH

Model T24.10.xx9

II 3G Ex nL/nA/ic Group IIC

C

sensor

+ C

cable

< C

O

C

O

= 200 µF

L

sensor

+ L

cable

< L

O

L

O

= 1000 mH

9. Further country-specific approvals

Model

Ex protection Approval No.

Approval

T24.10.xx6 intrinsically safe CSA 1248412

(LR105000-6)

CSA International

T24.10.xx8 intrinsically safe FM 3015886

FM Approvals

T24.10.xx2 II 1G EEx ia IIB/

IIC T4/T5/T6

2003EC02CP027-X INMETRO

T24.10.xxx

DE.C.32.001.A/

No. 15279

GOST Standard

T24.10.xx2 EEx ia IIB/IIC

T4~T6

GYJ04426X

NEPSI

For data for instrument versions T24.10.xx6 (CSA) and T24.10.008

(FM) see the relevant installation drawing (FM Installation Drawing see

Appendix 1 “FM Installation Drawing”).