WIKA operating instructions bypass level indicator model BNA

112195.01 11/2012 GB/D

5. Trouble shooting

5. Trouble shooting

The following table contains the most frequent causes of faults and the

necessary countermeasures.

Fault

Cause

Measure

Bypass level

indicator cannot

be fitted at the

planned place on

the vessel

Thread size or flange size of

the bypass level indicator do

not correlate

Modification of the vessel

Return to the factory

Thread on the fastening

sleeve on the vessel is faulty

Rework the thread or replace

the fastening sleeve

Mounting thread on the by-

pass level indicator is faulty

Return to the factory

Centre to centre distance of

the vessel does not correlate

with the bypass level indicator

Modification of the vessel

Return to the factory

Process connections are

not attached parallel to one

another

Modification of the vessel