Specifications, Dimensions in mm – WIKA A-IAI-1 Benutzerhandbuch

Seite 12

Advertising
background image

GB

WIKA operating instructions attachable indicator model A-IAI-1

12

14016825.01 02/2012 GB/D

3. Specifications

CE conformity

EMC directive

2004/108/EC, EN 61326 emission (group 1,

class B) and interference immunity (industrial

locations)

ATEX directive

94/9/EC, category 2G,

Ignition protection type Ex ia/ib IIC/IIB T4

EC-type examination certifi-

cate

EPS 11 ATEX 1 333 X

Safety-related maximum values

Power supply

U

i = DC 9 ... 28 V

Short circuit current

Ii = 100 mA

Power limitation

P

i = 1,200 mW

Maximum effective internal

capacitance

C

i

< 13 nF

Maximum effective internal

inductance

negligibly small

For further specifications see WIKA data sheet AC 80.07 and the order documen-

tation.

WARNING!

For further important safety instructions for operation in hazard-

ous areas see chapter 2.3 "Additional safety instructions for

instruments per ATEX".

Dimensions in mm

Advertising
Dieses Handbuch ist für die folgenden Produkte bezogen werden: