14016825.01 02/2012 GB/D
3. Specifications
CE conformity
EMC directive
2004/108/EC, EN 61326 emission (group 1,
class B) and interference immunity (industrial
locations)
ATEX directive
94/9/EC, category 2G,
Ignition protection type Ex ia/ib IIC/IIB T4
EC-type examination certifi-
cate
EPS 11 ATEX 1 333 X
Safety-related maximum values
Power supply
U
i = DC 9 ... 28 V
Short circuit current
Ii = 100 mA
Power limitation
P
i = 1,200 mW
Maximum effective internal
capacitance
C
i
< 13 nF
Maximum effective internal
inductance
negligibly small
For further specifications see WIKA data sheet AC 80.07 and the order documen-
tation.
WARNING!
For further important safety instructions for operation in hazard-
ous areas see chapter 2.3 "Additional safety instructions for
instruments per ATEX".
Dimensions in mm