Design and function, Specifications / 4. design and function – WIKA SC64 Benutzerhandbuch

Seite 10

Advertising
background image

10

WIKA operating instructions models SC58, SC64

14054366.01 10/2012 GB/D

GB

Environmental

conditions

Storage

temperature

Operating

temperature

Relative humidity

-20 … +70 °C

0 … 50 °C

max. 75 %, no condensation

CE conformity

EMC directive

Low voltage

directive

2004/108/EG, EN 61326 Emission (group 1, class B) and

interference immunity (industrial application)

2006/95/EG, EN 60730-1 and EN 60730-2-9

For further specifications see WIKA data sheets AC 85.24 (model SC58)

or AC 85.25 (model SC64) and the order documentation.

4. Design and function

4.1 Description

These temperature controllers feature simple operation and a high switch

rating. In comparison to mechanical thermostats, these temperature

controllers can handle significantly more switching cycles and thus have

a higher operating life.

The round design of the model SC64 enables it to be used as an

alternative to the purely-mechanical Combistat (model SC15).

The design of the model SC58 enables the controller to be used as

an alternative to the purely-mechanical remote-reading thermometer

(model TF58).

The instrument has been designed and built solely for the intended use

described here, and may only be used accordingly.

4.2 Scope of delivery

Cross-check scope of delivery with delivery note.