Technical data

General data and operating conditions

3

47

EDB712 DE/EN 2.1

3

Technical data

3.1

General data and operating conditions

Conformity

CE

Low-voltage directive (2006/95/EC)

EMC directive (2004/108/EC)

Degree of pollution

VDE 0110 part 2, degree of pollution 2

Climatic conditions

In accordance with EN 60721-3-1 to 60721-3-4

(no condensation, average relative humidity 85 %)

Storage

1K2 in accordance with IEC/EN 60721-3-1
Temperature

0 °C ... +45 °C

Transport

2K2 in accordance with IEC/EN 60721-3-2
Temperature

0 °C ... +45 °C

Operation

3K3 in accordance with IEC/EN 60721-3-3
Temperature

0 °C ... +45 °C For operating ambient temperatures

The ambient temperature must not exceed +45 °C.

Mounting positions

Vertical on a wall, terminals downward.

Mounting clearances

(

50)

Leakage current to PE

(in accordance with

EN 61800-5-1)

< 3.5 mA

Degree of protection

IP 00

Insulation strength

Overvoltage category III in accordance with VDE 0110

Mechanical strength

VDE 0160 (vibration test)