background image

Electrical installation

Connection plan

Expansion of the torque setting range

5

62

EDB712 DE/EN 2.1

5.3.4

Expansion of the torque setting range
As supplied the device is setup for operation without a neutral conductor. In this

case the torque setting range is approx. 1:20.
If a larger setting range is required, two measures must be taken:

ƒ

Connect the neutral conductor to the motor star point

ƒ

Replace the resistor on soldering terminals (position R420, fitted with

22 kΩ resistor from the factory) with a 100 kΩ resistor.

712_006

Fig. 8

Replacing the 22k

Ω

resistor with a 100 k

Ω

resistor at position R420