3 connection plan, Connection plan, Electrical installation – Lenze 712 E.3B Benutzerhandbuch
Seite 57
Advertising

Electrical installation
Connection plan
Drive controller type 712 for mains connection 340 ... 460 V
5
57
EDB712 DE/EN 2.1
5.3
Connection plan
5.3.1
Drive controller type 712 for mains connection 340 ... 460 V
L2
L1
PE
L3
M
3~
U
V
W
PE
L1 L2 L3
FF 16
A
712_002
Fig. 3
Connection, drive controller 712 for mains connection 340 ... 460 V
ƒ
The device is set in the factory to a mains voltage range of
340 ... 460 V ± 0%.
The device can be changed to the mains voltage range 190 ... 265 V ± 0%.
(
P. 26
)