Commissioning

Initial commissioning

6

64

EDB712 DE/EN 2.1

6.2

Initial commissioning

Step

Adjustment for setpoint selection using

potentiometer (terminals 7, 8, 9 ) or

master voltage (terminals 7, 8 )

Further adjustment on additional use of a

dancer potentiometer (terminals 12, 13,

14)

1.

Turn the trimmers ”U

max

, ”U

min

,

Tänzer (Dancer)to the left stop.

2.

Set the setpoint potentiometer or master

voltage to zero.

3.

Switch on the mains and close switch

”RFR”.
Adjustment of the minimum voltage

4.

Increase the motor speed by turning

trimmer ”U

min

” clockwise until the

required minimum torque is set.

If zero is required as the minimum torque,

turn trimmer ”U

min

” back until the motor

just ceases to rotate to avoid a dead band

on the setpoint potentiometer in the

bottom range.
Adjustment of the maximum voltage

5.

Set the setpoint potentiometer to

maximum or set master voltage to U

L

=

10 V.

6.

Increase the motor torque by turning the

trimmer ”U

max

” clockwise until the

required maximum torque is set.

The setting for the minimum torque is to

be checked because the minimum and

maximum voltage can affect each other.

7.

Set the setpoint potentiometer to the

middle position or set master voltage to

approx. 5 V.

8.

Using the trimmer ”Tänzer (Dancer)”, set

the required effect of the dancer

potentiometer.

Position ”E” reduces the motor voltage,

Position ”A” increases the motor voltage.

9.

.

After the adjustment of the effect of the

dancer, repeat the adjustment of the

minimum voltage (see step 4) with the

dancer potentiometer in position ”E”.

10.

Furthermore, repeat the calibration of the

maximum voltage (see steps 5 and 6) in

position ”A”.

11.

Commissioning is complete.