Electrical installation

Connection plan

Connection of control signals to the drive controller 712

5

61

EDB712 DE/EN 2.1

5.3.3

Connection of control signals to the drive controller 712

A

S

7

8

9

12 13 14 16 17

=

+

-

7

8

E

10K / 1 W lin.

A

S

E

10K

RFR

+

+

+

Controller

enable

Setpoint
potentiometer

Master voltage
U = 10 V

LN

Dancer

712_005

Fig. 7

Connection of setpoint signals and the controller enable

ƒ

The device can evaluate a setpoint signal from a potentiometer or master

voltage using terminals 7, 8 and 9. In addition, for winding applications a

second setpoint can be defined at terminals 12, 13 and 14 using a dancer

potentiometer.

ƒ

The drive controller is enabled using an external contact to be connected

to terminals 16 and 17. For this purpose a low current contact (10 V,

10 mA) is to be used.

Note!

Use suitable relay contacts if control signals are switched using a

relay.
The drive controller is enabled with switch RFR closed.
If RFR is opened, the enable pulse and the drive controller are reset.