Herstellererklärung sil (englisch), Declaration by the manufacturer – Richter RSS/F Series Bellows-Sealed Control Valves Benutzerhandbuch
Seite 25

Erstellt/
Prepared by
:
CRQ/MP
am/
on
: 18.03.13
Seite/
Page
: 1
QM-Nr./
QM-No.
: 0905-40-1049_RSS/4-01
Genehmigt/
Released by
: CRQ/MP
am/
on
: 18.03.13
von/
of
:
1
A Unit of IDEX Corporation
Kempen, 27.01.2011
SIL
Declaration by the Manufacturer
Functional Safety according to IEC 61508
We declare, that the devices
RSS
are suitable for use in a safety related application, if the safety instructions and the following
parameters are observed:
Device Type:
A
Proof Test Interval:
≤ 1 year
HFT:
0 (single channel usage)
λ
SU
:
224 FIT
λ
SD
:
37 FIT
λ
DU
:
197 FIT
λ
DD
:
64 FIT
SFF:
62,2 %
PFD
Avg
:
8,64 10
-4
(for T
Proof
= 1 year)
MTBF:
219 years
Safety Integrity Level:
SIL 2
The specified values are valid only for the valve. Accessories such as an actuator, solenoid
valves, limit switches etc. are not included.
______________________________ ______________________________
Gregor Kleining
Michael Pohlmann
Dir. Research & Development
Quality Manager