7 technical data, 1 technical data - electrical ratings, 3 technical data - electrical ratings (sinewave) – Baumer MQR3000F Benutzerhandbuch

Seite 28: Technical data, Technical data - electrical ratings, Technical data - electrical ratings (square-wave), Technical data - electrical ratings (sinewave)

Advertising
background image

25

Baumer_MQR3000F_II_DE-EN (14A4)

MB233 - 11111230

7

Technical data

7

Technical data

7.1

Technical data - electrical ratings

• Voltage supply:

4.75...30 VDC

• Consumption w/o load:

≤300 mA (24 VDC)

• Output signals:

SSI data (linedriver RS485)

• Position resolution:

0...20 bit singleturn

• Speed resolution:

≤18 bit (±20...±2000 rpm)

• Code:

Gray or binary

• Code sequence:

Positiv at CW

• Input signals:

SSI clock, set zero, counting direction

• Additional output signals:

Square-wave HTL or TTL/RS422, SinCos

• Status indicator:

Color-LED, «System OK» output

• Interference immunity:

EN 61000-6-2:2005

• Emitted interference:

EN 61000-6-3:2007/A1:2011

• Approval:

CE

7.2

Technical data - electrical ratings (square-wave)

• Pulses per revolution:

1024...4096 (As ordered)

• Phase shift:

90° ±2°

• Scan ratio:

45...55%

• Output frequency:

≤500 kHz (HTL)

≤2 MHz (TTL)

• Output signals:

A+, A-, B+, B-

• Output stages:

HTL

TTL/RS422

(As ordered)

7.3

Technical data - electrical ratings (sinewave)

• Sinewave cycles per turn:

1024...4096 (As ordered)

• Phase shift:

90° ±2°

• Output frequency:

≤500 kHz

• Output signals:

A+, A-, B+, B-

• Output stage:

SinCos 1 Vpp

Advertising